EUVIMEDEUVIMED entdecken
Open Access

The automatic recognition and counting of cough

Samantha J Barry, Adrie D Dane, Alyn H Morice, Anthony D Walmsley

Cough · 2006-12 · 2 (1)

DOI: 10.1186/1745-9974-2-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Cough, online erschienen am 28.09.2006. Verfasst von Samantha J Barry und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science and the Environment, University of Hull, Cottingham Road, Hull, HU6 7RX, UK. s.j.barry@chem.hull.ac.uk. Die Arbeit wurde bisher 149-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cough recordings have been undertaken for many years but the analysis of cough frequency and the temporal relation to trigger factors have proven problematic. Because cough is episodic, data collection over many hours is required, along with real-time aural analysis which is equally time-consuming. A method has been developed for the automatic recognition and counting of coughs in sound recordings.

Methods

The Hull Automatic Cough Counter (HACC) is a program developed for the analysis of digital audio recordings. HACC uses digital signal processing (DSP) to calculate characteristic spectral coefficients of sound events, which are then classified into cough and non-cough events by the use of a probabilistic neural network (PNN). Parameters such as the total number of coughs and cough frequency as a function of time can be calculated from the results of the audio processing. Thirty three smoking subjects, 20 male and 13 female aged between 20 and 54 with a chronic troublesome cough were studied in the hour after rising using audio recordings.

Results

Using the graphical user interface (GUI), counting the number of coughs identified by HACC in an hour long recording, took an average of 1 minute 35 seconds, a 97.5% reduction in counting time. HACC achieved a sensitivity of 80% and a specificity of 96%. Reproducibility of repeated HACC analysis is 100%.

Conclusion

An automated system for the analysis of sound files containing coughs and other non-cough events has been developed, with a high robustness and good degree of accuracy towards the number of actual coughs in the audio recording.

Autor:innen und Institutionen

  • Department of Chemistry, Faculty of Science and the Environment, University of Hull, Cottingham Road, Hull, HU6 7RX, UK. s.j.barry@chem.hull.ac.uk

Zitieren

APA

Barry, S. J., Dane, A. D., Morice, A. H., & Walmsley, A. D. (2006). The automatic recognition and counting of cough. Cough, 2(1). https://doi.org/10.1186/1745-9974-2-8

Vancouver

Barry SJ, Dane AD, Morice AH, Walmsley AD. The automatic recognition and counting of cough. Cough. 2006;2(1). doi:10.1186/1745-9974-2-8

BibTeX
@article{Barry2006,
  author = {Barry, Samantha J and Dane, Adrie D and Morice, Alyn H and Walmsley, Anthony D},
  title = {The automatic recognition and counting of cough},
  journal = {Cough},
  year = {2006},
  volume = {2},
  number = {1},
  doi = {10.1186/1745-9974-2-8}
}
Kostenlos starten →