Point positioning and counting network: A deep learning-based method for automatic axon counting
Experimental Eye Research · 2026-06 · 267 · 110968
DOI: 10.1016/j.exer.2026.110968 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Eye Research, 2026-06. Verfasst von Caiye Fan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Wenzhou University of Technology, Wenzhou, China. Hauptthemen laut MEDLINE: Deep Learning, Axons, Optic Nerve, Retinal Ganglion Cells. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Key Research and Development Program of Zhejiang Province, National Key Research and Development Program of China.
Abstract (Originalsprache)
Accurate quantification of axon density is pivotal in optic nerve-related studies, as axonal degeneration is a hallmark of numerous neurological disorders. This study introduces the Point Positioning and Counting Network (PPCNet), a novel point-annotation-based deep learning framework that overcomes the limitations of manual counting and existing automated tools. PPCNet integrates a VGG16 backbone with multiscale feature extraction and lateral fusion to generate high-resolution feature maps. A dual-branch architecture regresses spatial coordinates and classifies candidate points, enabling axonal-center localization and confidence scoring. An optimized Hungarian algorithm, incorporating Euclidean distance and confidence metrics, ensures one-to-one correspondence between predicted candidates and ground-truth points. The model is trained end-to-end using a hybrid loss combining mean squared error and cross-entropy. Evaluated on a goat optic nerve semi-thin section dataset, PPCNet significantly outperformed current state-of-the-art methods (Axonet 2.0 and AxonDeepSeg). In the test set, mean ± SD axon counts were 901.6 ± 225.6 for manual counting, 890.2 ± 227.3 for PPCNet, 918.8 ± 297.9 for Axonet2.0, and 1045 ± 275 for AxonDeepSeg. Linear regression analysis demonstrated superior agreement with manual counts (R2 = 0.939), surpassing Axonet 2.0 (R2 = 0.8612) and AxonDeepSeg (R2 = 0.9142). PPCNet also yielded a lower mean absolute error (MAE = 45.93) than those of the comparative models (97.50 and 146.33). Bland-Altman analysis confirmed narrower limits of agreement (-99.23 to 121.90) and reduced systematic bias. Confidence-interval analysis further supported PPCNet's reliability, showing substantial overlap with manual counts. In conclusion, PPCNet delivers sub-pixel-accurate automated axon quantification for optic nerve research, replacing tedious manual counting and traditional segmentation-based methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wenzhou University of Technology, Wenzhou, China.
- State Key Laboratory of Ophthalmology, Optometry and Vision Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China; Zhejiang Key Laboratory of Key Technologies for Visual Pathway Reconstruction, Eye Hospital,…
- Wenzhou University of Technology, Wenzhou, China. Electronic address: wangyy@wzut.edu.cn.
Förderung
- Key Research and Development Program of Zhejiang Province
- National Key Research and Development Program of China
Zitieren
APA
Fan, C., Huang, S., Huang, T., Yao, R., Wang, X., Tan, Z., Zhang, Y., & Wang, Y. (2026). Point positioning and counting network: A deep learning-based method for automatic axon counting. Experimental Eye Research, 267, 110968. https://doi.org/10.1016/j.exer.2026.110968
Vancouver
Fan C, Huang S, Huang T, Yao R, Wang X, Tan Z, et al. Point positioning and counting network: A deep learning-based method for automatic axon counting. Experimental Eye Research. 2026;267:110968. doi:10.1016/j.exer.2026.110968
BibTeX
@article{Fan2026,
author = {Fan, Caiye and Huang, Shurui and Huang, Tinghui and Yao, Rui and Wang, Xudong and Tan, Zuoping and Zhang, Yikui and Wang, Yuanyuan},
title = {Point positioning and counting network: A deep learning-based method for automatic axon counting},
journal = {Experimental Eye Research},
year = {2026},
volume = {267},
pages = {110968},
doi = {10.1016/j.exer.2026.110968}
}
EUVIMED