EUVIMEDEUVIMED entdecken
Crossref

Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients

Thomas Maribo, Elena Iversen, Niels Trolle Andersen, Kristian Stengaard-Pedersen, Berit Schiøttz-Christensen

International Musculoskeletal Medicine · 2009-12 · 31 (4) · 172-177

DOI: 10.1179/175361409x12472218841040 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Musculoskeletal Medicine, online erschienen am 18.07.2013. Verfasst von Thomas Maribo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods: Forty-eight patients with chronic low back pain advised to do exercise were included. A test protocol was established based on review of the literature and a pilot test. Patients were timed for their ability to stand on one leg with their eyes open and with eyes closed. After a 20-min break, the procedure was repeated to check for reproducibility.

Results

Eyes open: a ceiling effect was seen as more than 48% of patients were able to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91.

Conclusions

The One Leg Stand Test can be used to test postural balance in patients with chronic low back pain, as the reliability of the test was acceptable.

Zitieren

APA

Maribo, T., Iversen, E., Andersen, N. T., Stengaard-Pedersen, K., & Schiøttz-Christensen, B. (2009). Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients. International Musculoskeletal Medicine, 31(4), 172-177. https://doi.org/10.1179/175361409x12472218841040

Vancouver

Maribo T, Iversen E, Andersen NT, Stengaard-Pedersen K, Schiøttz-Christensen B. Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients. International Musculoskeletal Medicine. 2009;31(4):172-177. doi:10.1179/175361409x12472218841040

BibTeX
@article{Maribo2009,
  author = {Maribo, Thomas and Iversen, Elena and Andersen, Niels Trolle and Stengaard-Pedersen, Kristian and Schiøttz-Christensen, Berit},
  title = {Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients},
  journal = {International Musculoskeletal Medicine},
  year = {2009},
  volume = {31},
  number = {4},
  pages = {172--177},
  doi = {10.1179/175361409x12472218841040}
}
Kostenlos starten →