Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients
International Musculoskeletal Medicine · 2009-12 · 31 (4) · 172-177
DOI: 10.1179/175361409x12472218841040 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Musculoskeletal Medicine, online erschienen am 18.07.2013. Verfasst von Thomas Maribo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Objective
To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods: Forty-eight patients with chronic low back pain advised to do exercise were included. A test protocol was established based on review of the literature and a pilot test. Patients were timed for their ability to stand on one leg with their eyes open and with eyes closed. After a 20-min break, the procedure was repeated to check for reproducibility.
Results
Eyes open: a ceiling effect was seen as more than 48% of patients were able to stand for the maximum time, and no further analysis was done. Eyes closed: intra-observer reliability was tested in 21 patients; absolute reliability showed a standard error of the measurement (SEM) of 2.48 s and a minimal detectable change (MDC) of 6.88. The relative reliability was acceptable with an intra class correlation coefficient (ICC) of 0.86. Interobserver reliability was tested in 27 patients; absolute reliability showed a SEM of 1.42 s and a MDC of 3.95. The relative reliability was acceptable with an ICC of 0.91.
Conclusions
The One Leg Stand Test can be used to test postural balance in patients with chronic low back pain, as the reliability of the test was acceptable.
Zitieren
APA
Maribo, T., Iversen, E., Andersen, N. T., Stengaard-Pedersen, K., & Schiøttz-Christensen, B. (2009). Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients. International Musculoskeletal Medicine, 31(4), 172-177. https://doi.org/10.1179/175361409x12472218841040
Vancouver
Maribo T, Iversen E, Andersen NT, Stengaard-Pedersen K, Schiøttz-Christensen B. Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients. International Musculoskeletal Medicine. 2009;31(4):172-177. doi:10.1179/175361409x12472218841040
BibTeX
@article{Maribo2009,
author = {Maribo, Thomas and Iversen, Elena and Andersen, Niels Trolle and Stengaard-Pedersen, Kristian and Schiøttz-Christensen, Berit},
title = {Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients},
journal = {International Musculoskeletal Medicine},
year = {2009},
volume = {31},
number = {4},
pages = {172--177},
doi = {10.1179/175361409x12472218841040}
}
EUVIMED