Fachartikel in der Zeitschrift Journal of Diagnostic Medical Sonography, online erschienen am 21.12.2022. Verfasst von Hazal Kutlucan und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
The principal objective was to compare the diagnostic accuracy of two-dimensional transvaginal ultrasonography (2D TVUS), three-dimensional transvaginal ultrasonography (3D TVUS), and hysteroscopy with histopathology in patients with abnormal uterine bleeding. Materials and Methods: Fifty patients were included and underwent the three imaging methods. The negative predictive value, positive predictive value, sensitivity, and specificity of the methods were calculated. Determination of endometrial pathology and endometrial polyps by measuring the endometrial thickness, volume, and uterine area was examined.
Results
The complaint of menorrhagia was reported by 72.0% of participants. Histopathologically, 70.0% of the patients had endometrial polyps and leiomyoma being monitored. An endometrial polyp was detected in 58.0% of the patients by 2D TVUS, 80.0% by 3D TVUS, and 68.0% by hysteroscopy. While 2D TVUS demonstrated 65.71% accuracy in the detection of an endometrial polyp, 3D TVUS had an 80.0% accuracy, and hysteroscopy had a 77.77% accuracy. An endometrial polyp was detected when the uterine area was ≥237 mm 2 . If the endometrial thickness was over 10.5 mm, it was found to be related to an endometrial polyp. According to the volume measurements by 3D TVUS, the detection of an endometrial polyp was made with 96.4% sensitivity, provided that the pathology volume was ≥0.082 cm 3 .
Conclusion
In this cohort of patients, 3D TVUS achieved a high sensitivity to detect abnormalities and could be considered as an initial diagnostic modality, prior to the surgery, and may rival invasive procedures, such as hysteroscopy.
Zitieren
APA
Kutlucan, H., Işık, G., Akdulum, M. F. C., Demirdağ, E., Erdem, Ö., & Bozkurt, N. (2023). Comparison of Two-Dimensional Transvaginal Ultrasound, Three-Dimensional Transvaginal Ultrasound and Hysteroscopy to Diagnose in Patients With Abnormal Uterine Bleeding: A Retrospective Observational Study. Journal of Diagnostic Medical Sonography, 39(3), 238-248. https://doi.org/10.1177/87564793221140832
Vancouver
Kutlucan H, Işık G, Akdulum MFC, Demirdağ E, Erdem Ö, Bozkurt N. Comparison of Two-Dimensional Transvaginal Ultrasound, Three-Dimensional Transvaginal Ultrasound and Hysteroscopy to Diagnose in Patients With Abnormal Uterine Bleeding: A Retrospective Observational Study. Journal of Diagnostic Medical Sonography. 2023;39(3):238-248. doi:10.1177/87564793221140832
BibTeX
@article{Kutlucan2023,
author = {Kutlucan, Hazal and Işık, Gizem and Akdulum, Münire Funda Cevher and Demirdağ, Erhan and Erdem, Özlem and Bozkurt, Nuray},
title = {Comparison of Two-Dimensional Transvaginal Ultrasound, Three-Dimensional Transvaginal Ultrasound and Hysteroscopy to Diagnose in Patients With Abnormal Uterine Bleeding: A Retrospective Observational Study},
journal = {Journal of Diagnostic Medical Sonography},
year = {2023},
volume = {39},
number = {3},
pages = {238--248},
doi = {10.1177/87564793221140832}
}
EUVIMED