Diagnostic Accuracy of Transvaginal Sonography Compared with Hysteroscopy in Evaluation of Abnormal Uterine Bleeding: A Comparative Study
International Journal of Current Pharmaceutical Review and Research · 30.06.2026 · 18 (06)
DOI: 10.25258/ijcpr.18.6.271 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Current Pharmaceutical Review and Research, online erschienen am 30.06.2026. Verfasst von Sradha Suman Sahu und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Abnormal uterine bleeding is a frequent gynaecological complaint across reproductive, perimenopausal, and postmenopausal age groups. Transvaginal sonography is commonly used as the first-line imaging tool, while hysteroscopy allows direct visualization of the uterine cavity. Their comparative diagnostic yield remains clinically important, particularly where access, cost, and patient acceptability influence investigation pathways.
Objective
To compare the diagnostic accuracy of transvaginal sonography and hysteroscopy in women presenting with abnormal uterine bleeding, using final histopathology as the reference standard.
Methods
This comparative diagnostic accuracy study included 130 women with abnormal uterine bleeding who underwent transvaginal sonography, hysteroscopy, and histopathological assessment at Maharaja Krishna Chandra Gajapati (MKCG) Medical College, Berhampur, Odisha. The study was conducted over 18 months from January 2024 to June 2025. Diagnostic findings on transvaginal sonography and hysteroscopy were compared against final histopathology. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were calculated.
Results
The mean age was 45.8 ± 8.2 years. Premenopausal, perimenopausal, and postmenopausal women constituted 48 (36.9%), 38 (29.2%), and 44 (33.8%), respectively. Histopathology showed polyp in 43 (33.1%), normal endometrium in 43 (33.1%), fibroid in 16 (12.3%), hyperplasia in 16 (12.3%), atrophy in 6 (4.6%), and cancer in 6 (4.6%). TVS showed sensitivity 81.6%, specificity 74.4%, PPV 86.6%, NPV 66.7%, and accuracy 79.2%. Hysteroscopy showed sensitivity 100.0%, specificity 88.4%, PPV 94.6%, NPV 100.0%, and accuracy 96.2%. Correct classification was significantly higher with hysteroscopy than TVS (McNemar χ²=20.045, p
Zitieren
APA
Sahu, S. S., Rout, P. K., & Pradhan, P. P. (2026). Diagnostic Accuracy of Transvaginal Sonography Compared with Hysteroscopy in Evaluation of Abnormal Uterine Bleeding: A Comparative Study. International Journal of Current Pharmaceutical Review and Research, 18(06). https://doi.org/10.25258/ijcpr.18.6.271
Vancouver
Sahu SS, Rout PK, Pradhan PP. Diagnostic Accuracy of Transvaginal Sonography Compared with Hysteroscopy in Evaluation of Abnormal Uterine Bleeding: A Comparative Study. International Journal of Current Pharmaceutical Review and Research. 2026;18(06). doi:10.25258/ijcpr.18.6.271
BibTeX
@article{Sahu2026,
author = {Sahu, Sradha Suman and Rout, Prashanta Kumar and Pradhan, Pragyan Paramita},
title = {Diagnostic Accuracy of Transvaginal Sonography Compared with Hysteroscopy in Evaluation of Abnormal Uterine Bleeding: A Comparative Study},
journal = {International Journal of Current Pharmaceutical Review and Research},
year = {2026},
volume = {18},
number = {06},
doi = {10.25258/ijcpr.18.6.271}
}
EUVIMED