EUVIMEDEUVIMED entdecken
Crossref

Diagnostic Accuracy of Transvaginal Sonography in the Detection of Endometrial Polyps

Yevheniia Poliakova, Nataliia Lutsenko

Journal of Diagnostic Medical Sonography · 2020-01 · 36 (1) · 31-35

DOI: 10.1177/8756479319879374 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Diagnostic Medical Sonography, online erschienen am 09.10.2019. Verfasst von Yevheniia Poliakova und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Transvaginal sonography (TVS) is considered a simple and generally accepted method for detecting uterine anomalies. With TVS, the uterus can be clearly visualized, but so far, the diagnostic accuracy of TVS varies across different studies. This retrospective study was devised to evaluate the accuracy of a sonographic diagnosis of endometrial polyps in a Ukrainian hospital.

Methods

This was a single-center retrospective study of woman who underwent TVS and had hysteroscopy or dilation and curettage for endometrial pathology. A cohort of 156 women were included in this yearlong study. A comparative analysis was based on the preoperative diagnosis, according to TVS, compared with the postoperative histopathology results.

Results

The overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of TVS in diagnosing endometrial polyps were 69%, 51%, 73%, 46%, and 63%, respectively.

Conclusion

This retrospective study provided data on the lack of accuracy for a sonographic diagnosis of endometrial polyps. This was based on 26% of women whose diagnosis was not confirmed by histology. A false-negative result occurred for 54% of women who had polyps that were not detected at the preoperative stage. These data raise the question of the feasibility of further invasive procedures based on a single TVS study.

Zitieren

APA

Poliakova, Y., & Lutsenko, N. (2020). Diagnostic Accuracy of Transvaginal Sonography in the Detection of Endometrial Polyps. Journal of Diagnostic Medical Sonography, 36(1), 31-35. https://doi.org/10.1177/8756479319879374

Vancouver

Poliakova Y, Lutsenko N. Diagnostic Accuracy of Transvaginal Sonography in the Detection of Endometrial Polyps. Journal of Diagnostic Medical Sonography. 2020;36(1):31-35. doi:10.1177/8756479319879374

BibTeX
@article{Poliakova2020,
  author = {Poliakova, Yevheniia and Lutsenko, Nataliia},
  title = {Diagnostic Accuracy of Transvaginal Sonography in the Detection of Endometrial Polyps},
  journal = {Journal of Diagnostic Medical Sonography},
  year = {2020},
  volume = {36},
  number = {1},
  pages = {31--35},
  doi = {10.1177/8756479319879374}
}
Kostenlos starten →