Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea
Trends in Hearing · 2024-01 · 28
DOI: 10.1177/23312165241248973 ↗Kurz gefasst
Fachartikel in der Zeitschrift Trends in Hearing, online erschienen am 08.05.2024. Verfasst von Sabine Haumann und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Cochlea, Cochlear Implantation, Audiometry, Evoked Response, Cochlear Implants. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.
- Cluster of Excellence "Hearing4All", Hannover, Germany.
ORCID-Profile: Sabine Haumann
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Haumann, S., Timm, M. E., Büchner, A., Lenarz, T., & Salcher, R. B. (2024). Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea. Trends in Hearing, 28. https://doi.org/10.1177/23312165241248973
Vancouver
Haumann S, Timm ME, Büchner A, Lenarz T, Salcher RB. Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea. Trends in Hearing. 2024;28. doi:10.1177/23312165241248973
BibTeX
@article{Haumann2024,
author = {Haumann, Sabine and Timm, Max E and Büchner, Andreas and Lenarz, Thomas and Salcher, Rolf B},
title = {Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea},
journal = {Trends in Hearing},
year = {2024},
volume = {28},
doi = {10.1177/23312165241248973}
}
EUVIMED