Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring
Trends in Hearing · 2024
DOI: 10.1177/23312165241252240 ↗Kurz gefasst
Fachartikel in der Zeitschrift Trends in Hearing, 2024. Verfasst von Sabine Haumann und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Audiometry, Evoked Response, Cochlear Implantation, Auditory Threshold, Cochlear Implants. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
In recent years, tools for early detection of irreversible trauma to the basilar membrane during hearing preservation cochlear implant (CI) surgery were established in several clinics. A link with the degree of postoperative hearing preservation in patients was investigated, but patient populations were usually small. Therefore, this study's aim was to analyze data from intraoperative extracochlear electrocochleography (ECochG) recordings for a larger group. During hearing preservation CI surgery, extracochlear recordings were made before, during, and after CI electrode insertion using a cotton wick electrode placed at the promontory. Before and after insertion, amplitudes and stimulus response thresholds were recorded at 250, 500, and 1000 Hz. During insertion, response amplitudes were recorded at one frequency and one stimulus level. Data from 121 patient ears were analyzed. The key benefit of extracochlear recordings is that they can be performed before, during, and after CI electrode insertion. However, extracochlear ECochG threshold changes before and after CI insertion were relatively small and did not independently correlate well with hearing preservation, although at 250 Hz they added some significant information. Some tendencies—although no significant relationships—were detected between amplitude behavior and hearing preservation. Rising amplitudes seem favorable and falling amplitudes disadvantageous, but constant amplitudes do not appear to allow stringent predictions. Extracochlear ECochG measurements seem to only partially realize expected benefits. The questions now are: do gains justify the effort, and do other procedures or possible combinations lead to greater benefits for patients?
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.
- Cluster of Excellence "Hearing4All", Hannover, Germany.
- Department of Otorhinolaryngology, Proselis Klinikum Recklinghausen, Recklinghausen, Germany.
ORCID-Profile: Sabine Haumann
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Haumann, S., Mynarek Née Bradler, M., Maier, H., Helmstaedter, V., Büchner, A., Lenarz, T., & Teschner, M. J. (2024). Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring. Trends in Hearing. https://doi.org/10.1177/23312165241252240
Vancouver
Haumann S, Mynarek Née Bradler M, Maier H, Helmstaedter V, Büchner A, Lenarz T, et al. Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring. Trends in Hearing. 2024. doi:10.1177/23312165241252240
BibTeX
@article{Haumann2024,
author = {Haumann, Sabine and Mynarek Née Bradler, Marlene and Maier, Hannes and Helmstaedter, Victor and Büchner, Andreas and Lenarz, Thomas and Teschner, Magnus J},
title = {Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring},
journal = {Trends in Hearing},
year = {2024},
doi = {10.1177/23312165241252240}
}
EUVIMED