EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Biomechanical Comparison of Adjustable-Loop Femoral Cortical Suspension Devices for Soft Tissue ACL Reconstruction

Garrett Chapman, John Hannah, Neeraj Vij, Joseph N Liu, Martin J Morrison, Nirav Amin

Orthopaedic Journal of Sports Medicine · 01.02.2023 · 11 (2)

DOI: 10.1177/23259671221146788 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Journal of Sports Medicine, online erschienen am 16.02.2023. Verfasst von Garrett Chapman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Spine and Joint Institute, Redlands Community Hospital, Redlands, California, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Several new adjustable-loop devices (ALDs) for anterior cruciate ligament reconstruction (ACLR) have not been tested in vitro.

Purpose

To compare the biomechanical performances of 5 ALDs under a high cyclic load and forces representative of the return-to-play conditions seen in the recovering athlete. Study Design: Controlled laboratory study.

Methods

A total of 10 devices for each of 5 chosen ALDs (UltraButton [Smith & Nephew], RigidLoop [DePuy Mitek], ProCinch [Stryker], TightRope [Arthrex], and ToggleLoc [Biomet]) were tested in a device-only model. The devices were secured to a servohydraulic test machine and preconditioned from 10 to 75 N at a rate of 0.5 Hz for 20 cycles. They were then subjected to high cyclic forces (100-500 N for 4000 cycles) and subsequently pulled to failure at 50 mm/min. The preconditioning displacement, permanent deformation, cumulative peak displacement, stiffness coefficient, and load to failure data were collected.

Results

The UltraButton displayed the greatest preconditioning displacement (0.22 ± 0.20 mm), followed by the RigidLoop (0.11 ± 0.03 mm), ProCinch (0.07 ± 0.04 mm), TightRope (0.07 ± 0.02 mm), and ToggleLoc (0.02 ± 0.03 mm). The TightRope displayed the greatest permanent deformation (3.19 ± 1.03 mm) followed by the UltraButton (2.14 ± 0.92 mm), ToggleLoc (2.02 ± 1.09 mm), RigidLoop (1.67 ± 0.1 mm), and ProCinch (1.38 ± 0.18 mm). The TightRope displayed the greatest cumulative peak displacement (3.69 ± 1.03 mm) followed by the UltraButton (2.46 ± 0.92 mm), ToggleLoc (2.37 ± 1.08 mm), RigidLoop (2.01 ± 0.1 mm), and ProCinch (1.75 ± 0.19 mm). The UltraButton displayed the largest stiffness coefficient (1347.22 ± 136.33 N/mm) followed by the RigidLoop (1325.4 ± 116.37 N/mm), ToggleLoc (1216.62 ± 131.32 N/mm), ProCinch (1155.56 ± 88.04), and TightRope (848.48 ± 31.94). The ToggleLoc displayed the largest load to failure (1874.42 ± 101.08 N) followed by the RigidLoop (1614.12 ± 129.11 N), UltraButton (1391.69 ± 142.04 N), ProCinch (1384.85 ± 58.62 N), and TightRope (991.8 ± 51.1 N.)

Conclusion

The 5 ALDs exhibited different biomechanical properties. None of them had peak cumulative displacements for which the confidence interval lay above 3 mm, thus no single device was determined to have a higher rate of clinical failure compared with the others. Clinical Relevance: ALD choice may affect biomechanics after ACLR.

Schlagwörter

Stichwörter der Autor:innen

ACLadjustable loop devicecortical buttonligament reconstructionsports medicine

Autor:innen und Institutionen

  • Spine and Joint Institute, Redlands Community Hospital, Redlands, California, USA.
  • Loma Linda University School of Medicine, Loma Linda, California, USA.
  • University of Arizona College of Medicine-Phoenix, Phoenix, Arizona, USA.
  • Department of Orthopedic Surgery, Keck Hospital of University of Southern California, Los Angeles, California, USA.
  • Renown Pediatric Orthopedics and Scoliosis, University of Nevada, Reno School of Medicine, Reno, Nevada, USA.
  • Jerry L. Pettis Memorial Veterans Hospital, Loma Linda Healthcare System, Loma Linda, California, USA.

Zitieren

APA

Chapman, G., Hannah, J., Vij, N., Liu, J. N., Morrison, M. J., & Amin, N. (2023). Biomechanical Comparison of Adjustable-Loop Femoral Cortical Suspension Devices for Soft Tissue ACL Reconstruction. Orthopaedic Journal of Sports Medicine, 11(2). https://doi.org/10.1177/23259671221146788

Vancouver

Chapman G, Hannah J, Vij N, Liu JN, Morrison MJ, Amin N. Biomechanical Comparison of Adjustable-Loop Femoral Cortical Suspension Devices for Soft Tissue ACL Reconstruction. Orthopaedic Journal of Sports Medicine. 2023;11(2). doi:10.1177/23259671221146788

BibTeX
@article{Chapman2023,
  author = {Chapman, Garrett and Hannah, John and Vij, Neeraj and Liu, Joseph N and Morrison, Martin J and Amin, Nirav},
  title = {Biomechanical Comparison of Adjustable-Loop Femoral Cortical Suspension Devices for Soft Tissue ACL Reconstruction},
  journal = {Orthopaedic Journal of Sports Medicine},
  year = {2023},
  volume = {11},
  number = {2},
  doi = {10.1177/23259671221146788}
}
Kostenlos starten →