EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction

Richard C Lee iD, Steven D Voinier iD, Conor F McCarthy iD, Donald F Colantonio iD, Shawn M Gee iD, Christopher J Tucker iD, Melvin D Helgeson iD, Nicholas P Lopreiato iD

Orthopaedic Journal of Sports Medicine · 2025-02 · 13 (2)

DOI: 10.1177/23259671251318014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Journal of Sports Medicine, online erschienen am 18.02.2025. Verfasst von Richard C Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Society of Military Orthopaedic Surgeons: Military Orthopaedics and Readiness Optimization Research Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established. Purpose/Hypothesis: This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft. Study Design: Controlled laboratory study.

Methods

A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10–mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6–mm wide or 8–mm wide full-thickness QT along with a 10–mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure.

Results

The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT ( P = .004), 10-mm and 6-mm QT ( P < .001), 10-mm QT and 10-mm PT ( P < .001), and 8-mm QT and 10-mm PT grafts ( P < .001), but not between the 6-mm QT and 10-mm PT grafts ( P = .152).

Conclusion

The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts

Schlagwörter

Stichwörter der Autor:innen

anterior cruciate ligament reconstructionbiomechanicsquadriceps tendon graft

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, USA.
  • Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee, USA.
  • Extremity Trauma and Amputation Center of Excellence, Defense Health Agency, Falls Church, Virginia, USA.
  • Department of Orthopedic Surgery, Keller Army Community Hospital, West Point, New York, USA.

ORCID-Profile: Richard C Lee, Steven D Voinier, Conor F McCarthy, Donald F Colantonio, Shawn M Gee, Christopher J Tucker, Melvin D Helgeson, Nicholas P Lopreiato

Förderung

  • Society of Military Orthopaedic Surgeons: Military Orthopaedics and Readiness Optimization Research Grant

Zitieren

APA

Lee, R. C., Voinier, S. D., McCarthy, C. F., Colantonio, D. F., Gee, S. M., Tucker, C. J., Helgeson, M. D., & Lopreiato, N. P. (2025). Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction. Orthopaedic Journal of Sports Medicine, 13(2). https://doi.org/10.1177/23259671251318014

Vancouver

Lee RC, Voinier SD, McCarthy CF, Colantonio DF, Gee SM, Tucker CJ, et al. Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction. Orthopaedic Journal of Sports Medicine. 2025;13(2). doi:10.1177/23259671251318014

BibTeX
@article{Lee2025,
  author = {Lee, Richard C and Voinier, Steven D and McCarthy, Conor F and Colantonio, Donald F and Gee, Shawn M and Tucker, Christopher J and Helgeson, Melvin D and Lopreiato, Nicholas P},
  title = {Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction},
  journal = {Orthopaedic Journal of Sports Medicine},
  year = {2025},
  volume = {13},
  number = {2},
  doi = {10.1177/23259671251318014}
}
Kostenlos starten →