Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction
Orthopaedic Journal of Sports Medicine · 2025-02 · 13 (2)
DOI: 10.1177/23259671251318014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Orthopaedic Journal of Sports Medicine, online erschienen am 18.02.2025. Verfasst von Richard C Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Society of Military Orthopaedic Surgeons: Military Orthopaedics and Readiness Optimization Research Grant.
Abstract (Originalsprache)
Background
Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established. Purpose/Hypothesis: This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft. Study Design: Controlled laboratory study.
Methods
A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10–mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6–mm wide or 8–mm wide full-thickness QT along with a 10–mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure.
Results
The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT ( P = .004), 10-mm and 6-mm QT ( P < .001), 10-mm QT and 10-mm PT ( P < .001), and 8-mm QT and 10-mm PT grafts ( P < .001), but not between the 6-mm QT and 10-mm PT grafts ( P = .152).
Conclusion
The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Walter Reed National Military Medical Center, Bethesda, Maryland, USA.
- Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee, USA.
- Extremity Trauma and Amputation Center of Excellence, Defense Health Agency, Falls Church, Virginia, USA.
- Department of Orthopedic Surgery, Keller Army Community Hospital, West Point, New York, USA.
ORCID-Profile: Richard C Lee, Steven D Voinier, Conor F McCarthy, Donald F Colantonio, Shawn M Gee, Christopher J Tucker, Melvin D Helgeson, Nicholas P Lopreiato
Förderung
- Society of Military Orthopaedic Surgeons: Military Orthopaedics and Readiness Optimization Research Grant
Zitieren
APA
Lee, R. C., Voinier, S. D., McCarthy, C. F., Colantonio, D. F., Gee, S. M., Tucker, C. J., Helgeson, M. D., & Lopreiato, N. P. (2025). Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction. Orthopaedic Journal of Sports Medicine, 13(2). https://doi.org/10.1177/23259671251318014
Vancouver
Lee RC, Voinier SD, McCarthy CF, Colantonio DF, Gee SM, Tucker CJ, et al. Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction. Orthopaedic Journal of Sports Medicine. 2025;13(2). doi:10.1177/23259671251318014
BibTeX
@article{Lee2025,
author = {Lee, Richard C and Voinier, Steven D and McCarthy, Conor F and Colantonio, Donald F and Gee, Shawn M and Tucker, Christopher J and Helgeson, Melvin D and Lopreiato, Nicholas P},
title = {Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction},
journal = {Orthopaedic Journal of Sports Medicine},
year = {2025},
volume = {13},
number = {2},
doi = {10.1177/23259671251318014}
}
EUVIMED