EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Computed Tomography Scan Near Miss of an Intraorbital Wooden Foreign Body

Armin Farahvash iD, Annie M Q Wang, Felipe Cardemil iD, Hall F Chew, Harmeet S Gill, Oleh M Antonyshyn

Plastic Surgery · 2024-02 · 32 (1) · 158-161

DOI: 10.1177/22925503221101954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Plastic Surgery, online erschienen am 22.05.2022. Verfasst von Armin Farahvash und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

When intraorbital wooden foreign bodies are missed, the consequences can be devastating. While the gold standard diagnostic imaging is computed tomography (CT), it has low sensitivity. We present a 61-year-old man with a bamboo injury to his right eye. He underwent two CT scans that failed to raise the possibility of intraorbital foreign bodies. Upon additional review, a rectangular-shaped pocket of air was identified in the orbit which was most consistent with wooden foreign bodies based on the clinical history. A combined mid-lid approach followed by a transconjunctival and transcaruncular extension were employed to remove several wooden splinters. Postoperatively, due to recurrent orbital compartment syndrome, he required a second decompression with an inferior rim osteotomy. He had good recovery at 3 months follow-up. Overall, intraorbital wooden foreign bodies are challenging to diagnose due to imaging limitations. Providing a clear history and suspected diagnosis to radiology is critical for diagnosis.

Schlagwörter

Stichwörter der Autor:innen

computed tomographyinferior orbital rim osteotomyintraorbital foreign bodyorbital compartment syndromeorbital decompressionwooden foreign body

Autor:innen und Institutionen

  • Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
  • Division of Plastic, Reconstructive & Aesthetic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada.
  • Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.

ORCID-Profile: Armin Farahvash, Felipe Cardemil

Zitieren

APA

Farahvash, A., Wang, A. M. Q., Cardemil, F., Chew, H. F., Gill, H. S., & Antonyshyn, O. M. (2024). A Computed Tomography Scan Near Miss of an Intraorbital Wooden Foreign Body. Plastic Surgery, 32(1), 158-161. https://doi.org/10.1177/22925503221101954

Vancouver

Farahvash A, Wang AMQ, Cardemil F, Chew HF, Gill HS, Antonyshyn OM. A Computed Tomography Scan Near Miss of an Intraorbital Wooden Foreign Body. Plastic Surgery. 2024;32(1):158-161. doi:10.1177/22925503221101954

BibTeX
@article{Farahvash2024,
  author = {Farahvash, Armin and Wang, Annie M Q and Cardemil, Felipe and Chew, Hall F and Gill, Harmeet S and Antonyshyn, Oleh M},
  title = {A Computed Tomography Scan Near Miss of an Intraorbital Wooden Foreign Body},
  journal = {Plastic Surgery},
  year = {2024},
  volume = {32},
  number = {1},
  pages = {158--161},
  doi = {10.1177/22925503221101954}
}
Kostenlos starten →