Fallbericht in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 20.11.2023. Verfasst von Ashok Sharma und 1 weiteren Autor:innen. Beteiligte Einrichtung: Director, Dr Ashok Sharma's Cornea Centre SCO 2463-2464, Sector 22 C, Chandigarh, India. Hauptthemen laut MEDLINE: Eye Foreign Bodies. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A 55-year-old woman presented with a stromal wooden foreign body (FB) in the left cornea. The deep corneal stroma wooden FB was removed using vitreoretinal FB forceps as a scoop. In this innovative technique, a 26-gauge needle was used to open the track of the wooden FB. The FB was trapped in the concavity of one limb of the vitreoretinal FB forceps. The vitreoretinal forceps were gradually withdrawn and the FB was removed. The patient was treated with gatifloxacin and voriconazole six times, and atropine 1% three times daily. The patient did not develop infiltrate or hypopyon in 2 weeks. After 2 weeks, gatifloxacin and voriconazole were reduced to four times a day; and atropine to two times a day. After 6 weeks topical medication was stopped. The patient achieved a best-corrected visual acuity (OS) of 6/9 at 8 weeks and maintained it through 7 months of follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Eye Foreign BodiesFemaleHumansMiddle AgedGatifloxacinVoriconazoleSurgical InstrumentsAtropine Derivatives

Substanzen

GatifloxacinVoriconazoleAtropine Derivatives

Autor:innen und Institutionen

  • Director, Dr Ashok Sharma's Cornea Centre SCO 2463-2464, Sector 22 C, Chandigarh, India.
  • Consultant, Cornea Centre SCO 2463-2464, Sector 22 C, Chandigarh, India.

Zitieren

APA

Sharma, A., & Sharma, R. (2023). Retrieval of deep corneal stromal wooden foreign body using vitreoretinal foreign body forceps as scoop: An innovative technique. Indian Journal of Ophthalmology, 71(12), 3718-3720. https://doi.org/10.4103/ijo.ijo_801_23

Vancouver

Sharma A, Sharma R. Retrieval of deep corneal stromal wooden foreign body using vitreoretinal foreign body forceps as scoop: An innovative technique. Indian Journal of Ophthalmology. 2023;71(12):3718-3720. doi:10.4103/ijo.ijo_801_23

BibTeX
@article{Sharma2023,
  author = {Sharma, Ashok and Sharma, Rajan},
  title = {Retrieval of deep corneal stromal wooden foreign body using vitreoretinal foreign body forceps as scoop: An innovative technique},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  volume = {71},
  number = {12},
  pages = {3718--3720},
  doi = {10.4103/ijo.ijo_801_23}
}
Kostenlos starten →