EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Fracture resistance evaluation of CAD/CAM zirconia and composite primary molar crowns with different occlusal thicknesses

Arif Bolaca iD, Yıldırım Erdoğan

Journal of Applied Biomaterials & Functional Materials · 2024

DOI: 10.1177/22808000241235994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Biomaterials & Functional Materials, 2024. Verfasst von Arif Bolaca und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Dentistry, Faculty of Dentistry, Pamukkale University, Denizli, Turkey. Hauptthemen laut MEDLINE: Crowns, Zirconium. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: pamukkale üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the effect of different CAD/CAM materials and occlusal thicknesses on the fracture resistance of primary molar crowns.

Methods

Sixty extracted primary molar teeth were prepared and randomly divided into six experimental groups according to the material and thickness. Primary molar crowns with a central groove thickness of 0.3 and 0.5 mm were fabricated from CAD/CAM zirconia (group Z), zirconia-reinforced lithium silicate (group ZLS), and pre-polymerized composite resin blocks (group C). Each crown was cemented with self-adhesive resin cement on the prepared tooth. All specimens were subjected to fracture tests until fracture. Fracture load values were recorded in Newtons (N). Data were statistically analyzed using a two-way analysis of variance (ANOVA) followed by Tukey multiple comparison test.

Results

The highest fracture load values were obtained in group Z at 0.5 mm occlusal thickness and were significantly higher compared with the other experimental groups ( p < 0.05). Although the lowest fracture load values were obtained in group ZLS at 0.3 mm occlusal thickness, all the tested CAD/CAM primary molar crowns at both thicknesses demonstrated fracture load values exceeding reported chewing force in pediatric patients.

Conclusion

CAD/CAM primary molar crowns with reduced occlusal thickness may be used for the full-coverage restoration of primary molar teeth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrownsZirconiumHumansChildMaterials TestingComputer-Aided DesignDental PorcelainCeramicsDental Prosthesis Design

Stichwörter der Autor:innen

CAD/CAM materialsfracture resistanceocclusal thicknessprimary molar crowns

Substanzen

zirconium oxideZirconiumDental Porcelain

Autor:innen und Institutionen

  • Department of Pediatric Dentistry, Faculty of Dentistry, Pamukkale University, Denizli, Turkey.

ORCID-Profile: Arif Bolaca

Förderung

  • pamukkale üniversitesi

Zitieren

APA

Bolaca, A., & Erdoğan, Y. (2024). Fracture resistance evaluation of CAD/CAM zirconia and composite primary molar crowns with different occlusal thicknesses. Journal of Applied Biomaterials & Functional Materials. https://doi.org/10.1177/22808000241235994

Vancouver

Bolaca A, Erdoğan Y. Fracture resistance evaluation of CAD/CAM zirconia and composite primary molar crowns with different occlusal thicknesses. Journal of Applied Biomaterials & Functional Materials. 2024. doi:10.1177/22808000241235994

BibTeX
@article{Bolaca2024,
  author = {Bolaca, Arif and Erdoğan, Yıldırım},
  title = {Fracture resistance evaluation of CAD/CAM zirconia and composite primary molar crowns with different occlusal thicknesses},
  journal = {Journal of Applied Biomaterials & Functional Materials},
  year = {2024},
  doi = {10.1177/22808000241235994}
}
Kostenlos starten →