Accuracy and Safety of a Triad-Dependent Technique for Subaxial Cervical Pedicle Screw Placement: A Prospective Cohort Study
Global Spine Journal · 2026-11 · 16 (8) · 4057-4070
DOI: 10.1177/21925682261454294 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Global Spine Journal, online erschienen am 21.05.2026. Verfasst von Mohamed El-Meshtawy und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Study Design Prospective single-arm cohort study.
Objectives
Cervical pedicle screws (CPS) offer superior biomechanical stability compared with lateral mass screws. However, their widespread adoption is constrained by narrow pedicle safety margins and the potential risk of neurovascular injury. This study aimed to describe the rationale of a novel triad-dependent technique (TDT) for subaxial CPS placement and to evaluate its accuracy and safety.
Methods
Between May 2023 and April 2025, 63 consecutive patients undergoing posterior subaxial (C3–C6) cervical instrumentation at our institution were screened for eligibility. CPS were inserted using the TDT, which integrates individualized morphometric preoperative planning, intraoperative fluoroscopic guidance, and continuous tactile monitoring via mini-laminotomy. Postoperative CT was used to assess screw accuracy using the 2-mm breach classification. Multinomial logistic regression was performed to identify risk factors for breach.
Results
A total of 204 CPS were inserted in 41 patients. No breach was observed in 174 screws (85.3%), while 30 screws (14.7%) demonstrated breach, including 18 medial and 12 lateral violations. No neurovascular complications were observed in this cohort. Pedicle diameter
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.
- Orthopedic and Trauma Rehabilitation Unit, Department of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.
- Department of Rehabilitation Sciences, Center for Rehabilitation Research, Texas Tech University Health Sciences Center, Lubbock, TX, USA.
ORCID-Profile: Belal Elnady, Mahmoud Fouad Ibrahim
Zitieren
APA
El-Meshtawy, M., Saleh, M. A., Ibrahim, M. A., Elnady, B., & Ibrahim, M. F. (2026). Accuracy and Safety of a Triad-Dependent Technique for Subaxial Cervical Pedicle Screw Placement: A Prospective Cohort Study. Global Spine Journal, 16(8), 4057-4070. https://doi.org/10.1177/21925682261454294
Vancouver
El-Meshtawy M, Saleh MA, Ibrahim MA, Elnady B, Ibrahim MF. Accuracy and Safety of a Triad-Dependent Technique for Subaxial Cervical Pedicle Screw Placement: A Prospective Cohort Study. Global Spine Journal. 2026;16(8):4057-4070. doi:10.1177/21925682261454294
BibTeX
@article{ElMeshtawy2026,
author = {El-Meshtawy, Mohamed and Saleh, Mahmoud Abdelrahman and Ibrahim, Mariam A and Elnady, Belal and Ibrahim, Mahmoud Fouad},
title = {Accuracy and Safety of a Triad-Dependent Technique for Subaxial Cervical Pedicle Screw Placement: A Prospective Cohort Study},
journal = {Global Spine Journal},
year = {2026},
volume = {16},
number = {8},
pages = {4057--4070},
doi = {10.1177/21925682261454294}
}
EUVIMED