EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Design and preliminary bench-level validation of a low-cost 3D-printed hip–knee exoskeleton for lower-limb rehabilitation training

Md Fazle Rabbi, Helal An Nahiyan, Sourav Karmaker iD, Fahim Islam Anik

Journal of Rehabilitation and Assistive Technologies Engineering · 2026-07 · 13

DOI: 10.1177/20556683261474539 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Rehabilitation and Assistive Technologies Engineering, online erschienen am 30.07.2026. Verfasst von Md Fazle Rabbi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Khulna University of Engineering & Technology, Khulna, Bangladesh. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lower-limb impairment caused by neurological injury, musculoskeletal disorders, or reduced mobility often requires repetitive rehabilitation exercises, but continuous therapist-assisted therapy may be difficult to access in low-resource settings. In this study, we developed and preliminarily evaluated a low-cost, lightweight, portable hip–knee exoskeleton prototype capable of generating controlled hip and knee joint motion for rehabilitation-oriented range-of-motion training. The prototype was constructed mainly of 3D-printed polylactic acid parts and powered by a pair of high-torque servo motors in the hip and knee joints. A Bluetooth-connected Android app was programmed to offer two modes: rehabilitation mode for independent joint control and a gait-inspired sinusoidal mode that generates coordinated hip and knee joint trajectories. The cost of the materials used to construct the prototype is estimated to be USD 155 with a weight of about 2.1 kg. Joint motion performance was assessed through time-angle measurements at three predefined speed settings. The hip joint (approximately 60° movement) was achieved in 2.2, 1.6, and 1.1 s and the knee joint (approximately 140° movement) was achieved in 3.0, 2.0, and 0.6 s for slow, medium and fast modes, respectively. The trial-to-trial variation in commanded servo position remained below ±1° under the tested conditions. The results demonstrate the feasibility of generating repeatable commanded hip and knee joint motion under controlled laboratory conditions. However, further investigations involving quantitative load-bearing evaluation, safety assessment, user studies, and clinical trials are required before the system can be considered for practical rehabilitation applications.

Schlagwörter

Stichwörter der Autor:innen

3D printingassistive technologybench-level validationhip–knee exoskeletonlower-limb rehabilitationmobile-app controlrehabilitation engineeringwearable robotics

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Khulna University of Engineering & Technology, Khulna, Bangladesh.

ORCID-Profile: Sourav Karmaker

Zitieren

APA

Rabbi, M. F., Nahiyan, H. A., Karmaker, S., & Anik, F. I. (2026). Design and preliminary bench-level validation of a low-cost 3D-printed hip–knee exoskeleton for lower-limb rehabilitation training. Journal of Rehabilitation and Assistive Technologies Engineering, 13. https://doi.org/10.1177/20556683261474539

Vancouver

Rabbi MF, Nahiyan HA, Karmaker S, Anik FI. Design and preliminary bench-level validation of a low-cost 3D-printed hip–knee exoskeleton for lower-limb rehabilitation training. Journal of Rehabilitation and Assistive Technologies Engineering. 2026;13. doi:10.1177/20556683261474539

BibTeX
@article{Rabbi2026,
  author = {Rabbi, Md Fazle and Nahiyan, Helal An and Karmaker, Sourav and Anik, Fahim Islam},
  title = {Design and preliminary bench-level validation of a low-cost 3D-printed hip–knee exoskeleton for lower-limb rehabilitation training},
  journal = {Journal of Rehabilitation and Assistive Technologies Engineering},
  year = {2026},
  volume = {13},
  doi = {10.1177/20556683261474539}
}
Kostenlos starten →