Assessing the validity of pressure-measuring insoles in quantifying gait variables

Jessica DeBerardinis, Janet S Dufek, Mohamed B Trabia, Daniel E Lidstone iD

Journal of Rehabilitation and Assistive Technologies Engineering · 2018-01 · 5

DOI: 10.1177/2055668317752088 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Rehabilitation and Assistive Technologies Engineering, online erschienen am 12.01.2018. Verfasst von Jessica DeBerardinis und 3 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Mechanical Engineering, University of Nevada Las Vegas, Las Vegas, USA. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: University of Nevada, Las Vegas.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Pressure-measuring insoles can provide a portable alternative to existing gait analysis tools. However, there is disagreement among researchers on their accuracy and the appropriate calibration methods. The purposes of this study were to (1) determine the validity of pressure-measuring insoles for calculating stance time and support-phase impulse during walking using two calibration procedures, and (2) examine the effect of insole size on the results.

Methods

Data were collected from 39 participants (23.5 ± 3.24 yrs, 66.7 ± 17.5 kg, 1.64 ± 0.09 m), each wearing appropriately sized insoles as they walked over two consecutive force platforms. Two calibration methods were evaluated: (1) manufacturer’s recommendation, and (2) a participant weight-based approach. Qualitative and quantitative evaluations were conducted.

Results

The results indicated that the insoles measured longer stance times than the force platform (differences are less than 10%). Both calibration methods resulted in inaccurate impulse values (differences are 30 and 50% for the two calibration methods, respectively). The results showed that when using the first calibration method, impulse values depended on insole size. The second calibration consistently underestimated the impulse.

Conclusions

It was concluded that while the insoles provide acceptable qualitative representation of the gait, the two studied calibration methods may lead to a misleading quantitative assessment.

Schlagwörter

Stichwörter der Autor:innen

Kineticslocomotionstance timesupport-phase impulsewalking

Autor:innen und Institutionen

  • 1Department of Mechanical Engineering, University of Nevada Las Vegas, Las Vegas, USA.
  • 2Department of Kinesiology and Nutrition Sciences, University of Nevada Las Vegas, Las Vegas, USA.

ORCID-Profile: Daniel E Lidstone

Förderung

  • University of Nevada, Las Vegas

Zitieren

APA

DeBerardinis, J., Dufek, J. S., Trabia, M. B., & Lidstone, D. E. (2018). Assessing the validity of pressure-measuring insoles in quantifying gait variables. Journal of Rehabilitation and Assistive Technologies Engineering, 5. https://doi.org/10.1177/2055668317752088

Vancouver

DeBerardinis J, Dufek JS, Trabia MB, Lidstone DE. Assessing the validity of pressure-measuring insoles in quantifying gait variables. Journal of Rehabilitation and Assistive Technologies Engineering. 2018;5. doi:10.1177/2055668317752088

BibTeX
@article{DeBerardinis2018,
  author = {DeBerardinis, Jessica and Dufek, Janet S and Trabia, Mohamed B and Lidstone, Daniel E},
  title = {Assessing the validity of pressure-measuring insoles in quantifying gait variables},
  journal = {Journal of Rehabilitation and Assistive Technologies Engineering},
  year = {2018},
  volume = {5},
  doi = {10.1177/2055668317752088}
}
Kostenlos starten →