EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

Effects of Medium Cut-Off Versus High-Flux Hemodialysis Membranes on Biomarkers: A Systematic Review and Meta-Analysis

Maryam Kandi, Romina Brignardello-Petersen, Rachel Couban, Celina Wu, Gihad Nesrallah iD

Canadian Journal of Kidney Health and Disease · 2022-01 · 9

DOI: 10.1177/20543581211067090 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Canadian Journal of Kidney Health and Disease, online erschienen am 18.01.2022. Verfasst von Maryam Kandi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Research Methods, Evidence & Impact, McMaster University, Hamilton, ON, Canada. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Baxter Healthcare Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Medium cut-off (MCO) membranes enhance large middle-molecule clearance while selectively retaining molecules >45 000 Da.

Objectives

We undertook a systematic review and meta-analysis comparing the effects of MCO versus high-flux membranes on biomarkers.

Methods

We searched MEDLINE, Embase, CINAHL, Cochrane Library, and Web of Science from January 2015 to July 2020, and gray literature sources from 2017. We included randomized (RS) and nonrandomized studies (NRS) comparing MCO and high-flux membranes in adults (>18 years) receiving maintenance hemodialysis. We performed study selection, data extraction, and quality appraisals in duplicate and used the Grading of Recommendations Assessment, Development, and Evaluation framework. Outcomes included solute removal (plasma clearance or dialysate quantitation), reduction ratios, and predialysis serum concentrations for a range of prespecified large middle molecules.

Results

We identified 26 eligible studies (10 RS and 16 NRS; N = 1883 patients; patient-years = 1366.3). The mean difference (MD) for albumin removal was 2.31 g per session (95% confidence interval [CI], 2.79 to 1.83; high certainty), with a reduction in predialysis albumin of −0.12 g/dl (95% CI, −0.16 to −0.07; I 2 = 0%; high certainty) in the first 24 weeks, returning to normal (MD = −0.02 g/dl, 95% CI, −0.07 to −0.03; I 2 = 56%; high certainty) after 24 weeks. We also found with high certainty that MCO dialysis resulted in a large increase (standardized mean difference [SMD]> 2.0 for all) in β2-microglobulin, κ- and λ-free light chains, and myoglobin removal, resulting in moderate (SMD > 0.5) to large (SMD > 0.8) reductions in predialysis concentrations for all of these solutes. Medium cut-off dialysis increased the reduction ratio for tumor necrosis factor-alpha (TNF-α) by 7.7% (95% CI, 4.7 to 10.6; moderate certainty), and reduced predialysis TNF-α by SMD −0.48 (95% CI, −0.91 to −0.04; moderate certainty). We found with moderate certainty that MCO dialysis had little to no effect on predialysis interleukin-6 (IL-6) plasma concentrations. Medium cut-off dialysis reduced mRNA expression of TNF-α and IL-6 in peripheral leukocytes by MD −15% (95% CI, −19.6 to −10.4; moderate certainty) and −8.8% (95% CI, −10.2 to −7.4; moderate certainty), respectively.

Conclusion

Medium cut-off dialysis increases the clearance of a wide range of large middle molecules and likely reduces inflammatory mediators with a concomitant transient reduction in serum albumin concentration. The net effect of MCO dialysis on large middle molecules could translate into important clinical effects.

Schlagwörter

Stichwörter der Autor:innen

Theranovadialysis outcomesexpanded hemodialysislarge middle moleculesmedium cut-offmeta-analysis

Autor:innen und Institutionen

  • Department of Health Research Methods, Evidence & Impact, McMaster University, Hamilton, ON, Canada.
  • University of Toronto, ON, Canada.
  • Nephrology Program, Humber River Hospital, Toronto, ON, Canada.

ORCID-Profile: Gihad Nesrallah

Förderung

  • Baxter Healthcare Corporation

Zitieren

APA

Kandi, M., Brignardello-Petersen, R., Couban, R., Wu, C., & Nesrallah, G. (2022). Effects of Medium Cut-Off Versus High-Flux Hemodialysis Membranes on Biomarkers: A Systematic Review and Meta-Analysis. Canadian Journal of Kidney Health and Disease, 9. https://doi.org/10.1177/20543581211067090

Vancouver

Kandi M, Brignardello-Petersen R, Couban R, Wu C, Nesrallah G. Effects of Medium Cut-Off Versus High-Flux Hemodialysis Membranes on Biomarkers: A Systematic Review and Meta-Analysis. Canadian Journal of Kidney Health and Disease. 2022;9. doi:10.1177/20543581211067090

BibTeX
@article{Kandi2022,
  author = {Kandi, Maryam and Brignardello-Petersen, Romina and Couban, Rachel and Wu, Celina and Nesrallah, Gihad},
  title = {Effects of Medium Cut-Off Versus High-Flux Hemodialysis Membranes on Biomarkers: A Systematic Review and Meta-Analysis},
  journal = {Canadian Journal of Kidney Health and Disease},
  year = {2022},
  volume = {9},
  doi = {10.1177/20543581211067090}
}
Kostenlos starten →