Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration
Journal of Clinical Medicine · 07.03.2025 · 14 (6) · 1798
DOI: 10.3390/jcm14061798 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 07.03.2025. Verfasst von Matteo Marcello und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, Dialysis and Transplant, San Bortolo Hospital, 36100 Vicenza, Italy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Removal of large uraemic toxins is still a challenge. Haemodiafiltration (HDF) has produced some results, although large convective volume, optimal vascular access to increase the blood flow rate and strict water quality management are required. Medium cut-off, high-retention-onset membranes have been recently developed, introducing the concept therapy called expanded haemodialysis (HDx). Furthermore, vitamin E-coated membrane has potential beneficial effects on inflammation and oxidative stress.
Methods
A prospective longitudinal multicentre study was conducted for 3 months among 24 chronic haemodialysis patients. Patients were randomly assigned into either HDF with high-flux membrane or HDx with Theranova or ViE-X membrane. The primary goal was to assess albumin loss among the three types of dialyzers. Secondary goals included assessment of depurative efficacy for uraemic toxins and clinical outcomes.
Results
Mean albumin loss was significantly higher in patients undergoing HDx with Theranova membrane, without any difference in serum albumin concentration among the three groups. Instantaneous clearance of small and middle molecules was significantly higher in patients undergoing HDF, but we did not find differences in removal ratio and Kt/V. Reduction in the erythropoietin resistance index was observed in patients treated with ViE-X membrane due to their lower dialysis vintage.
Conclusions
The higher albumin loss during HDx has no effects on pre-dialysis serum albumin. HDx with Theranova in the presence of lower session length, lower Qb, lower convective dose, and lower instantaneous clearance reached the same dialysis efficacy compared to HDF.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nephrology, Dialysis and Transplant, San Bortolo Hospital, 36100 Vicenza, Italy.
- International Renal Research Institute of Vicenza, 36100 Vicenza, Italy.
- Department of Nephrology, San Raffaele Hospital, 20132 Milan, Italy.
- Department of Nephrology and Dialysis, San Bassiano Hospital, 36061 Bassano, Italy.
ORCID-Profile: Matteo Marcello, Grazia Maria Virzì, Carlotta Caprara, Claudia Benedetti, Claudio Ronco
Zitieren
APA
Marcello, M., Simonini, M., Lorenzin, A., Corradi, V., Virzì, G. M., Caprara, C., Brendolan, A., Benedetti, C., Lentini, P., Zanella, M., & Ronco, C. (2025). Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration. Journal of Clinical Medicine, 14(6), 1798. https://doi.org/10.3390/jcm14061798
Vancouver
Marcello M, Simonini M, Lorenzin A, Corradi V, Virzì GM, Caprara C, et al. Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration. Journal of Clinical Medicine. 2025;14(6):1798. doi:10.3390/jcm14061798
BibTeX
@article{Marcello2025,
author = {Marcello, Matteo and Simonini, Marco and Lorenzin, Anna and Corradi, Valentina and Virzì, Grazia Maria and Caprara, Carlotta and Brendolan, Alessandra and Benedetti, Claudia and Lentini, Paolo and Zanella, Monica and Ronco, Claudio},
title = {Assessment of Safety and Efficacy of Expanded Hemodialysis with Medium Cut-Off Dialyzer Compared to Haemodiafiltration},
journal = {Journal of Clinical Medicine},
year = {2025},
volume = {14},
number = {6},
pages = {1798},
doi = {10.3390/jcm14061798}
}
EUVIMED