High-Flow Nasal Cannula Reduces Ventilatory Requirements During Endobronchial Ultrasound
Respiratory Care · 2026
DOI: 10.1177/19433654251412342 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Respiratory Care, 2026. Verfasst von Jeffrey Miechels und 2 weiteren Autor:innen. Beteiligte Einrichtung: Mr. Miechels is affiliated with the Department of Anesthesiology, Rijnstate Hospital, Arnhem, The Netherlands. Hauptthemen laut MEDLINE: Cannula, Pulmonary Disease, Chronic Obstructive, Endosonography, Oxygen Inhalation Therapy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Background
High-flow nasal cannula (HFNC) reduces dead-space ventilation, but this effect is diminished by open-mouth breathing and partial airway obstruction. Consequently, it is uncertain whether HFNC provides respiratory support during endobronchial ultrasound (EBUS) procedures.
Methods
A single-center randomized controlled crossover study was conducted at the Rijnstate Hospital, Arnhem, the Netherlands, from November 2022 to August 2024. Patients with severe COPD (Gold III/IV) were evaluated to determine if HFNC reduces dead space ventilation during an EBUS procedure. Exclusion criteria were known neurodegenerative conditions, allergies to propofol or esketamine, pregnancy, upper-airway obstructions, or severe pulmonary hypertension. Subjects received two sequences of HFNC flow (30 and 70 L/min or vice versa) during EBUS. The primary outcome was CO 2 washout, determined by a 60-s capnography trace with and without HFNC flow to measure the difference in inspiratory, end-tidal CO 2 , and β-angle.
Results
Twenty subjects with severe COPD (Gold III/IV) were included (Group A n = 10; Group B n = 10), of which one could not complete the bronchial measurements because of an obstructing carcinoma. CO 2 washout at carina was observed at 70 L/min of HFNC flow, demonstrated by a reduced inspiratory CO 2 of mean 6.0 mm Hg (95% CI: 4.5–8.3, P < .001) and end-tidal CO 2 of 5.3 mm Hg (95% CI: 2.3–7.5, P = .002), but not at 30 L/min of HFNC flow (mean inspiratory CO 2 difference of 1.5 mm Hg (95% CI: −2.3 to 6.0, P = .69) and mean end-tidal CO 2 difference of 0.8 mm Hg (95% CI: −2.3 to 3.0, P = .35). A flow of 70 L/min reduced inspiratory CO 2 in the left main bronchus (mean = 5.3 mm Hg; 95% CI: 2.3–8.3, P < .001), but not the end-tidal CO 2 (mean = 3.0 mm Hg; 95% CI: 0.0–6.0, P = .07).
Conclusions
An HFNC flow of 70 L/min reduced dead-space ventilation in subjects with severe COPD undergoing EBUS procedures during deep sedation, suggesting respiratory support during this procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Mr. Miechels is affiliated with the Department of Anesthesiology, Rijnstate Hospital, Arnhem, The Netherlands.
- Dr. Claessens is affiliated with the Department of Pulmonology, Rijnstate Hospital, Arnhem, The Netherlands.
- Dr. Koning is affiliated with the Department of Anesthesiology and Critical Care, Rijnstate Hospital, Arnhem, The Netherlands.
Zitieren
APA
Miechels, J., Claessens, N. J. M., & Koning, M. V. (2026). High-Flow Nasal Cannula Reduces Ventilatory Requirements During Endobronchial Ultrasound. Respiratory Care. https://doi.org/10.1177/19433654251412342
Vancouver
Miechels J, Claessens NJM, Koning MV. High-Flow Nasal Cannula Reduces Ventilatory Requirements During Endobronchial Ultrasound. Respiratory Care. 2026. doi:10.1177/19433654251412342
BibTeX
@article{Miechels2026,
author = {Miechels, Jeffrey and Claessens, Niels J M and Koning, Mark V},
title = {High-Flow Nasal Cannula Reduces Ventilatory Requirements During Endobronchial Ultrasound},
journal = {Respiratory Care},
year = {2026},
doi = {10.1177/19433654251412342}
}
EUVIMED