Randomisierte kontrollierte Studie in der Zeitschrift Respiratory Care, 2024. Verfasst von Felix-Antoine Vézina und 11 weiteren Autor:innen. Beteiligte Einrichtung: Institut Universitaire de Cardiologie et de Pneumologie de Québec-Université Laval, Québec City, Québec, Canada; and Centre Hospitalier Universitaire…. Hauptthemen laut MEDLINE: Dyspnea, Lung Diseases, Oxygen, Oxygen Inhalation Therapy. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: Exercise-induced O 2 desaturation contributes to dyspnea and exercise intolerance in various respiratory diseases. This study assessed whether automated O 2 titration was superior to fixed-flow O 2 to improve exertional dyspnea and walking exercise endurance. We also aimed at evaluating possible additive effects of high-flow nasal cannula coupled with automated O 2 titration on these outcomes. METHODS: Subjects with chronic respiratory diseases and exercise-induced desaturation performed a 3-min constant-speed shuttle test (CSST) and an endurance shuttle walking test (ESWT) with either (1) fixed-flow O 2 , (2) automated O 2 titration targeting an S pO 2 of 94% (± 2%), and (3) automated O 2 titration + high-flow nasal cannula according to a randomized sequence. The main outcome was Borg dyspnea score at the end of the 3-min CSST. Secondary outcomes included endurance time and dyspnea during ESWT and oxygenation status during exercise. RESULTS: Ten subjects with COPD, 10 with interstitial lung disease, 5 with pulmonary hypertension, and 3 with cystic fibrosis completed the study. Compared to fixed-flow O 2 , automated O 2 titration did not reduce dyspnea at the end of the 3-min CSST. Endurance time during the ESWT was prolonged with automated O 2 titration (mean difference 298 [95% CI 205–391] s, P < .001), and dyspnea at isotime was reduced. No further improvement was noted when high-flow nasal cannula was added to automated O 2 titration. Compared to fixed-flow O 2 , O 2 flows were higher with automated O 2 titration, resulting in better oxygenation. CONCLUSIONS: Automated O 2 titration was superior to fixed-flow O 2 to alleviate dyspnea and improve exercise endurance during the ESWT in subjects with a variety of chronic respiratory diseases. Adding high-flow nasal cannula to automated O 2 titration provided no further benefits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institut Universitaire de Cardiologie et de Pneumologie de Québec-Université Laval, Québec City, Québec, Canada; and Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, Québec City, Québec, Canada.
- Institut Universitaire de Cardiologie et de Pneumologie de Québec-Université Laval, Québec City, Québec, Canada.
- Institut Universitaire de Cardiologie et de Pneumologie de Québec-Université Laval, Québec City, Québec, Canada; and Université Grenoble Alpes, Laboratoire Hypoxie-Physiopathologie HP2 INSERM U1300, Grenoble, France.
- Institut Universitaire de Cardiologie et de Pneumologie de Québec-Université Laval, Québec City, Québec, Canada. francois.maltais@med.ulaval.ca.
Zitieren
APA
Vézina, F. A., Bouchard, P. A., Breton-Gagnon, É., Dion, G., Viglino, D., Roy, P., Bilodeau, L., Provencher, S., Denault, M. H., Saey, D., Lellouche, F., & Maltais, F. (2024). Automated O 2 Titration Alone or With High-Flow Nasal Cannula During Walking Exercise in Chronic Lung Diseases. Respiratory Care. https://doi.org/10.4187/respcare.10810
Vancouver
Vézina FA, Bouchard PA, Breton-Gagnon É, Dion G, Viglino D, Roy P, et al. Automated O 2 Titration Alone or With High-Flow Nasal Cannula During Walking Exercise in Chronic Lung Diseases. Respiratory Care. 2024. doi:10.4187/respcare.10810
BibTeX
@article{Vzina2024,
author = {Vézina, Felix-Antoine and Bouchard, Pierre-Alexandre and Breton-Gagnon, Émilie and Dion, Geneviève and Viglino, Damien and Roy, Pascalin and Bilodeau, Lara and Provencher, Steeve and Denault, Marie-Hélène and Saey, Didier and Lellouche, François and Maltais, François},
title = {Automated O 2 Titration Alone or With High-Flow Nasal Cannula During Walking Exercise in Chronic Lung Diseases},
journal = {Respiratory Care},
year = {2024},
doi = {10.4187/respcare.10810}
}
EUVIMED