Syndesmotic Suture Button Fixation Results in Higher Tegner Activity Scale Scores When Compared to Screw Fixation: A Multicenter Investigation
Foot & Ankle Specialist · 2024
DOI: 10.1177/19386400231174829 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Foot & Ankle Specialist, 2024. Verfasst von Mitchel R Obey und 7 weiteren Autor:innen. Beteiligte Einrichtung: Washington University in St. Louis, St. Louis, Missouri. Hauptthemen laut MEDLINE: Bone Screws, Fracture Fixation, Internal, Ankle Injuries. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
Background
Suture buttons and metal screws have been used and compared in biomechanical, radiographic, and clinical outcome studies for syndesmotic injuries, with neither implant demonstrating clear superiority. The aim of this study was to compare clinical outcomes of both implants.
Methods
Patients who underwent syndesmosis fixation at 2 separate academic centers from 2010 through 2017 were compared. Thirty-one patients treated with a suture button and 21 patients treated with screws were included. Patients in each group were matched by age, sex, and Orthopaedic Trauma Association fracture classification. Tegner Activity Scale (TAS), Foot and Ankle Ability Measure (FAAM), patient satisfaction score, surgical failure, and reoperation rates were compared.
Results
Patients who underwent suture button fixation had significantly higher TAS scores than those who underwent screw fixation (p < 0.001). There was no significant difference in FAAM ADL scores between cohorts (p = 0.08). Symptomatic hardware removal rates were similar (3.2% suture button cohort vs 9.0% in screw cohort). One patient (4.5%) underwent revision surgery secondary to syndesmotic malreduction after screw fixation, for a reoperation rate of 13.5%.
Conclusion
Patients with unstable syndesmotic injuries treated with suture button fixation had higher mean TAS scores compared to patients treated with screws. Foot and Ankle Ability Measure and ADL scores in these cohorts were similar. Level of Evidence: Level 3 Retrospective Matched Case-Cohort
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Washington University in St. Louis, St. Louis, Missouri.
- School of Data Science and Analytics, Kennesaw State University, Kennesaw, Georgia.
- Stanford School of Medicine, Palo Alto, California.
- Hospital for Special Surgery, New York City, New York.
- Steadman Philippon Research Institute, Vail, Colorado.
- School of Medicine, Washington University in St. Louis, St. Louis, Missouri.
ORCID-Profile: Kevin Schafer, Thomas O Clanton, Jonathon D Backus
Zitieren
APA
Obey, M. R., Schafer, K., Matheny, L. M., McAndrew, C. M., Gardner, M. J., Ricci, W. M., Clanton, T. O., & Backus, J. D. (2024). Syndesmotic Suture Button Fixation Results in Higher Tegner Activity Scale Scores When Compared to Screw Fixation: A Multicenter Investigation. Foot & Ankle Specialist. https://doi.org/10.1177/19386400231174829
Vancouver
Obey MR, Schafer K, Matheny LM, McAndrew CM, Gardner MJ, Ricci WM, et al. Syndesmotic Suture Button Fixation Results in Higher Tegner Activity Scale Scores When Compared to Screw Fixation: A Multicenter Investigation. Foot & Ankle Specialist. 2024. doi:10.1177/19386400231174829
BibTeX
@article{Obey2024,
author = {Obey, Mitchel R and Schafer, Kevin and Matheny, Lauren M and McAndrew, Christopher M and Gardner, Michael J and Ricci, William M and Clanton, Thomas O and Backus, Jonathon D},
title = {Syndesmotic Suture Button Fixation Results in Higher Tegner Activity Scale Scores When Compared to Screw Fixation: A Multicenter Investigation},
journal = {Foot & Ankle Specialist},
year = {2024},
doi = {10.1177/19386400231174829}
}
EUVIMED