Use of Continuous Glucose Monitoring and Insulin Pump Technologies in People With Type 2 Diabetes: Insights From a Survey of Health Care Professionals and Patients in Germany, Austria, and Switzerland
Journal of Diabetes Science and Technology · 2026-07 · 20 (4) · 1070-1079
DOI: 10.1177/19322968261444041 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Diabetes Science and Technology, online erschienen am 06.05.2026. Verfasst von Mirjam Elisabeth Eiswirth und 11 weiteren Autor:innen. Beteiligte Einrichtung: diateam, Bad Mergentheim, Germany. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 2, Continuous Glucose Monitoring, Insulin Infusion Systems, Insulin. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: abbott diabetes care, Ascensia Diabetes Care, dexcom.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Background
Diabetes technologies, such as continuous glucose monitoring (CGM), insulin pumps, and automated insulin delivery (AID) systems, are increasingly used by people with type 2 diabetes (PWT2D), with growing clinical evidence supporting their therapeutic benefit. To describe the extent of adoption, perceived benefits, and future expectations, both health care professionals (HCPs) and PWT2D data from the dt-report 2025 were analyzed.
Methods
From November to December 2025, HCP and PWT2D participated in the dt-report providing their attitudes, expectations, and predictions regarding the use of diabetes technology in type 2 diabetes. Frequencies from specific responses were analyzed.
Results
Data from 1078 HCPs and 450 PWT2D from the DACH region were analyzed for questions regarding the use of technology in type 2 diabetes. Continuous glucose monitoring was the most widely endorsed technology across both groups, with 58% of the survey participants using a CGM, and 1% using a pump. Health care professionals estimated 87% of PWT2D on intensive insulin therapy would benefit from CGM and saw indications among non-intensive insulin users (62%) and those on oral therapies (55%). Future use of CGM and AID systems was anticipated by both HCPs and PWT2D, including many currently not using such systems. Smart pens and stand-alone insulin pumps were viewed less favorably. Reported barriers included lack of awareness, reimbursement limitations, digital literacy, and usability concerns.
Conclusion
The findings indicate growing openness toward diabetes technologies among PWT2D and broader perceived indications among HCPs. However, uptake remains limited, particularly outside of intensive insulin therapy. These insights are of relevance for future clinical guidance, access strategies, and patient education.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- diateam, Bad Mergentheim, Germany.
- Research Institute of the Diabetes-Academy Bad Mergentheim (FIDAM), Germany.
- Barmherzige Brüder Konventhospital Linz, Austria.
- Diabetes Center Berne, Switzerland.
- Institute for Infectious Diseases, University of Bern, Switzerland.
- Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital, University of Bern, Switzerland.
ORCID-Profile: Mirjam Elisabeth Eiswirth, Michael Resl, Bernhard Kulzer, Timm Roos, Cordelia Trümpy, Maria Luisa Balmer, Lilian Witthauer, Julia K Mader, Peter Diem, Lutz Heinemann, Dominic Ehrmann, Norbert Hermanns
Förderung
- abbott diabetes care
- Ascensia Diabetes Care
- dexcom
- insulet corporation
- medtronic
- roche diabetes care
- sanofi
- Ypsomed Diabetes Care
Zitieren
APA
Eiswirth, M. E., Resl, M., Kulzer, B., Roos, T., Trümpy, C., Balmer, M. L., Witthauer, L., Mader, J. K., Diem, P., Heinemann, L., Ehrmann, D., & Hermanns, N. (2026). Use of Continuous Glucose Monitoring and Insulin Pump Technologies in People With Type 2 Diabetes: Insights From a Survey of Health Care Professionals and Patients in Germany, Austria, and Switzerland. Journal of Diabetes Science and Technology, 20(4), 1070-1079. https://doi.org/10.1177/19322968261444041
Vancouver
Eiswirth ME, Resl M, Kulzer B, Roos T, Trümpy C, Balmer ML, et al. Use of Continuous Glucose Monitoring and Insulin Pump Technologies in People With Type 2 Diabetes: Insights From a Survey of Health Care Professionals and Patients in Germany, Austria, and Switzerland. Journal of Diabetes Science and Technology. 2026;20(4):1070-1079. doi:10.1177/19322968261444041
BibTeX
@article{Eiswirth2026,
author = {Eiswirth, Mirjam Elisabeth and Resl, Michael and Kulzer, Bernhard and Roos, Timm and Trümpy, Cordelia and Balmer, Maria Luisa and Witthauer, Lilian and Mader, Julia K and Diem, Peter and Heinemann, Lutz and Ehrmann, Dominic and Hermanns, Norbert},
title = {Use of Continuous Glucose Monitoring and Insulin Pump Technologies in People With Type 2 Diabetes: Insights From a Survey of Health Care Professionals and Patients in Germany, Austria, and Switzerland},
journal = {Journal of Diabetes Science and Technology},
year = {2026},
volume = {20},
number = {4},
pages = {1070--1079},
doi = {10.1177/19322968261444041}
}
EUVIMED