Observational Study of the Impact of Infusion Set Replacement in Insulin Pump Users on Glycemic Management
Journal of Diabetes Science and Technology · 2026-11 · 20 (6) · 1862-1871
DOI: 10.1177/19322968251345837 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Diabetes Science and Technology, online erschienen am 28.06.2025. Verfasst von Kai Yoshimura und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Diabetes and Endocrinology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan. Hauptthemen laut MEDLINE: Insulin Infusion Systems, Diabetes Mellitus, Type 1, Blood Glucose, Insulin. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Although several studies have evaluated the impact of prolonged infusion set use in insulin pump users on glycemic management with the use of continuous glucose monitoring (CGM), real-world assessments without intervention have been unavailable.
Methods
This retrospective observational study recruited individuals with type 1 diabetes who received insulin pump therapy with real-time CGM. Insulin pump and CGM logs were extracted from the Medtronic CareLink system, and a dataset was constructed programmatically, counting tracking days from infusion set replacement every 24 hours up to day 4. The primary outcome was mean sensor glucose (SG) level, and the impact of infusion set usage duration on glycemic management was assessed.
Results
The study enrolled 45 individuals with a median age of 40 (interquartile range = 32-51) years and median body mass index of 22.5 (21.2-23.8) kg/m². Mean SG was significantly higher on day 4 (median of 151.9 [136.5-173.7] mg/dL) than on day 2 (144.4 [124.0-162.9] mg/dL, P = .024). Similarly, time above range (TAR), time in range (TIR), and time in tight range (TITR) had worsened on day 4 compared with day 2. The TAR increased from a median of 22.0% (7.3%-35.8%) on day 2 to 27.6% (17.7%-44.9%) on day 4, whereas TIR decreased from 74.2% (59.9%-87.1%) to 66.5% (52.0%-79.8%) and TITR decreased from 47.6% (37.1%-67.5%) to 42.2% (34.6%-54.1%).
Conclusions
Our evaluation of the real-world impact of prolonged infusion set use revealed an association between longer use and worsening of glycemic management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Diabetes and Endocrinology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
ORCID-Profile: Kai Yoshimura, Shin Urai, Kaori Hozumi, Mei Nakatsuji, Shuichiro Saito, Seiji Nishikage, Akane Yamamoto, Tomofumi Takayoshi, Wataru Ogawa, Yushi Hirota
Zitieren
APA
Yoshimura, K., Urai, S., Hozumi, K., Nakatsuji, M., Saito, S., Nishikage, S., Yamamoto, A., Takayoshi, T., Ogawa, W., & Hirota, Y. (2026). Observational Study of the Impact of Infusion Set Replacement in Insulin Pump Users on Glycemic Management. Journal of Diabetes Science and Technology, 20(6), 1862-1871. https://doi.org/10.1177/19322968251345837
Vancouver
Yoshimura K, Urai S, Hozumi K, Nakatsuji M, Saito S, Nishikage S, et al. Observational Study of the Impact of Infusion Set Replacement in Insulin Pump Users on Glycemic Management. Journal of Diabetes Science and Technology. 2026;20(6):1862-1871. doi:10.1177/19322968251345837
BibTeX
@article{Yoshimura2026,
author = {Yoshimura, Kai and Urai, Shin and Hozumi, Kaori and Nakatsuji, Mei and Saito, Shuichiro and Nishikage, Seiji and Yamamoto, Akane and Takayoshi, Tomofumi and Ogawa, Wataru and Hirota, Yushi},
title = {Observational Study of the Impact of Infusion Set Replacement in Insulin Pump Users on Glycemic Management},
journal = {Journal of Diabetes Science and Technology},
year = {2026},
volume = {20},
number = {6},
pages = {1862--1871},
doi = {10.1177/19322968251345837}
}
EUVIMED