EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth Rupture

Joost Johannes Antonius Stultiens iD, Xinli Du iD, Jérôme Joseph Waterval iD, Angélica Pérez Fornos, Nils Guinand, Raymond van de Berg

Journal of Otolaryngology - Head & Neck Surgery · 2026-05 · 55

DOI: 10.1177/19160216261433549 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Otolaryngology - Head & Neck Surgery, online erschienen am 08.05.2026. Verfasst von Joost Johannes Antonius Stultiens und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, School for Mental Health and Neuroscience, Faculty of Health Medicine and Life Sciences, Maa…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Semicircular Canals, Ear, Inner. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance Progress in vestibular implantation offers hope for patients with bilateral vestibulopathy. However, surgically opening the semicircular canals risks breaching the membranous labyrinth, which may induce sensorineural hearing loss. A robotic drill sensing force and torque might prevent membranous labyrinth rupture. Primary objective To assess the feasibility of force- and torque-based automatic cessation in a hand-guided robotic drill for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. Secondary objective To fit an electrode dummy through the fenestrations.

Design

Feasibility study using human cadaveric temporal bones.

Setting

Laboratory.

Participants

Ten formalin-fixed human temporal bones.

Intervention

After performing a cortical mastoidectomy and skeletonizing the semicircular canals, a hand-guided robotic drill was used to drill 2 fenestrations in each semicircular canal. A silicone electrode dummy was inserted through each fenestration. Main outcome measures Proportion of fenestrations with intact membranous labyrinth, as evaluated with a surgical microscope. Proportion of fenestrations allowing electrode insertion without additional manipulation.

Results

A total of 60 fenestrations were made in 30 semicircular canals from 10 temporal bones. Technical issues related to drill bit fixation occurred in 6 fenestrations. The remaining 54 fenestrations were all made without visible damage to the membranous labyrinth. In 81% of these fenestrations (44/54), the electrode could be advanced without requiring additional manipulation. The technical issue was related to improper alignment of the drill bit, leading to incorrect force and torque sensing.

Conclusions

Force- and torque-based automatic cessation in a hand-guided robotic drill is feasible for fenestrating the bony semicircular canals without rupturing the membranous labyrinth. However, improved burr fixation is required for consistent and reliable performance. Relevance The investigated approach holds potential to improve safety and precision in semicircular canal surgery, such as vestibular implantation. This may expand treatment options for patients with residual inner ear function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresSemicircular CanalsEar, InnerHumansFeasibility StudiesCadaverTemporal BoneMastoidectomy

Stichwörter der Autor:innen

bilateral vestibulopathyfeasibility studiesimplanted electrodesinner earprosthesis implantationrobot-assisted surgeryroboticssemicircular canalssurgical proceduresvestibular implant

Autor:innen und Institutionen

  • Department of Otorhinolaryngology-Head and Neck Surgery, School for Mental Health and Neuroscience, Faculty of Health Medicine and Life Sciences, Maastricht University Medical Center, Maastricht, The Netherlands.
  • Department of Mechanical and Aerospace Engineering, College of Engineering, Design and Physical Sciences, Brunel University of London, Uxbridge, UK.
  • Division of Otorhinolaryngology-Head and Neck Surgery, Department of Clinical Neurosciences, Geneva University Hospitals, University of Geneva, Geneva, Switzerland.

ORCID-Profile: Joost Johannes Antonius Stultiens, Xinli Du, Jérôme Joseph Waterval

Zitieren

APA

Stultiens, J. J. A., Du, X., Waterval, J. J., Pérez Fornos, A., Guinand, N., & van de Berg, R. (2026). A Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth Rupture. Journal of Otolaryngology - Head & Neck Surgery, 55. https://doi.org/10.1177/19160216261433549

Vancouver

Stultiens JJA, Du X, Waterval JJ, Pérez Fornos A, Guinand N, van de Berg R. A Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth Rupture. Journal of Otolaryngology - Head & Neck Surgery. 2026;55. doi:10.1177/19160216261433549

BibTeX
@article{Stultiens2026,
  author = {Stultiens, Joost Johannes Antonius and Du, Xinli and Waterval, Jérôme Joseph and Pérez Fornos, Angélica and Guinand, Nils and van de Berg, Raymond},
  title = {A Hand-Guided Robotic Drill for Vestibular Implant Surgery—Feasibility of Preventing Membranous Labyrinth Rupture},
  journal = {Journal of Otolaryngology - Head & Neck Surgery},
  year = {2026},
  volume = {55},
  doi = {10.1177/19160216261433549}
}
Kostenlos starten →