Intra-rater reliability of grip strength measurements in severely restricted hands
Hand Therapy · 27.07.2026
DOI: 10.1177/17589983261472043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hand Therapy, online erschienen am 27.07.2026. Verfasst von Ümit Uğurlu. Beteiligte Einrichtung: Department of Occupational Therapy, Faculty of Health Sciences, Bezmialem Vakıf University, Istanbul, Türkiye. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
Grip strength (GS) is a crucial indicator of hand function; however, its reliable assessment in individuals with severe hand dysfunction remains a clinical challenge. This study evaluated the intra-rater reliability of GS and grip pressure (GP) using the Jamar dynamometer and a modified sphygmomanometer (ModSp) in patients with complex bilateral hand dysfunction. Secondary objectives included determining the correlation between the instruments and exploring patient preferences.
Method
Fifty-two individuals with severe bilateral hand dysfunction due to systemic sclerosis were assessed as a representative model. A standardized measurement protocol was followed for both instruments. Intra-rater reliability was analyzed using intraclass correlation coefficients (ICCs), and linear regression was used to derive conversion formulas. Patient preferences were recorded using standardized open-ended questions and analyzed via thematic content analysis.
Results
Both instruments demonstrated excellent ICCs (0.96–0.98). Strong positive correlations were found between instrument scores (r = 0.88–0.91, p < 0.001), and regression models explained 78–82% of the variance. However, Bland–Altman analysis revealed systematic bias and relatively wide limits of agreement, indicating the methods are not interchangeable. Regarding preferences, 69.2% of participants favored the ModSp, citing greater comfort, better adaptation to deformities, and reduced pain during grasp, while 17.3% preferred the Jamar dynamometer and 13.5% reported no preference.
Conclusion
The Jamar and ModSp devices demonstrated excellent intra-rater reliability for grip assessment in severe hand dysfunction. While strongly correlated, they are not directly interchangeable for precise monitoring. The ModSp offers a practical, patient-centered alternative when standard dynamometry is hindered by physical constraints.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Occupational Therapy, Faculty of Health Sciences, Bezmialem Vakıf University, Istanbul, Türkiye.
- Division of Rheumatology, Department of Internal Medicine, Cerrahpaşa Faculty of Medicine, Istanbul University-Cerrahpaşa, Istanbul, Türkiye.
ORCID-Profile: Ümit Uğurlu
Zitieren
APA
Uğurlu, Ü. (2026). Intra-rater reliability of grip strength measurements in severely restricted hands. Hand Therapy. https://doi.org/10.1177/17589983261472043
Vancouver
Uğurlu Ü. Intra-rater reliability of grip strength measurements in severely restricted hands. Hand Therapy. 2026. doi:10.1177/17589983261472043
BibTeX
@article{Uurlu2026,
author = {Uğurlu, Ümit},
title = {Intra-rater reliability of grip strength measurements in severely restricted hands},
journal = {Hand Therapy},
year = {2026},
doi = {10.1177/17589983261472043}
}
EUVIMED