Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series
Shoulder & Elbow · 2026-10 · 18 (6) · 1322-1329
DOI: 10.1177/17585732261423892 ↗Kurz gefasst
Fachartikel in der Zeitschrift Shoulder & Elbow, online erschienen am 25.02.2026. Verfasst von Tanguy Segers und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, AZ Sint Jan Brugge, AZ Sint-Lucas Brugge, Bruges, Belgium. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Aims
Augmented Reality (AR) guidance has demonstrated improved accuracy in glenoid component placement in both in-vitro and in-vivo settings. In cases of severe glenoid wear, structural bone may allow for defect correction. This study evaluates the accuracy of glenoid component positioning and graft incorporation in angled bony-increased offset reverse shoulder arthroplasty (BIO-RSA) assisted by navigated AR.
Methods
Fifteen shoulders with severe glenoid erosion underwent angled BIO-RSA between 2021 and 2023. Preoperative computed tomographic (CT) scans facilitated three-dimensional (3D) surgical planning. Intraoperatively, glenoid placement was guided by navigated AR. Postoperative CT scans at six months were analyzed for graft incorporation and compared with preoperative planning to assess implant positioning accuracy.
Results
The mean deviation between preoperative planning and postoperative positioning was 4.1° ± 3.4° (range, 0°–11°) in baseplate version and 1.9° ± 2.4° (range, 0°–9°) in inclination. Baseplate entry-point deviation was 1.6 mm ± 1.2 mm (range, 0.5–4.0 mm) in the antero-posterior direction and 1.1 mm ± 1.1 mm (range, 0–4.5 mm) in the superior-inferior direction. The mean deviation in baseplate offset reconstruction was 2.1 mm ± 1.6 mm (range, 0–5.5 mm). Complete graft incorporation was observed in all cases.
Conclusion
Navigated AR enhances precision in BIO-RSA, ensuring accurate correction of glenoid wear and adherence to preoperative 3D planning. Level of evidence Retrospective radiological study.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, AZ Sint Jan Brugge, AZ Sint-Lucas Brugge, Bruges, Belgium.
ORCID-Profile: Tanguy Segers, Joris Beckers
Zitieren
APA
Segers, T., Beckers, J., Van Isacker, T., Pierreux, P., & Berghs, B. (2026). Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series. Shoulder & Elbow, 18(6), 1322-1329. https://doi.org/10.1177/17585732261423892
Vancouver
Segers T, Beckers J, Van Isacker T, Pierreux P, Berghs B. Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series. Shoulder & Elbow. 2026;18(6):1322-1329. doi:10.1177/17585732261423892
BibTeX
@article{Segers2026,
author = {Segers, Tanguy and Beckers, Joris and Van Isacker, Tom and Pierreux, Pieter and Berghs, Bart},
title = {Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series},
journal = {Shoulder & Elbow},
year = {2026},
volume = {18},
number = {6},
pages = {1322--1329},
doi = {10.1177/17585732261423892}
}