EUVIMEDEUVIMED entdecken
Open Access

Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series

Tanguy Segers iD, Joris Beckers iD, Tom Van Isacker, Pieter Pierreux, Bart Berghs

Shoulder & Elbow · 2026-10 · 18 (6) · 1322-1329

DOI: 10.1177/17585732261423892 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Shoulder & Elbow, online erschienen am 25.02.2026. Verfasst von Tanguy Segers und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, AZ Sint Jan Brugge, AZ Sint-Lucas Brugge, Bruges, Belgium. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Augmented Reality (AR) guidance has demonstrated improved accuracy in glenoid component placement in both in-vitro and in-vivo settings. In cases of severe glenoid wear, structural bone may allow for defect correction. This study evaluates the accuracy of glenoid component positioning and graft incorporation in angled bony-increased offset reverse shoulder arthroplasty (BIO-RSA) assisted by navigated AR.

Methods

Fifteen shoulders with severe glenoid erosion underwent angled BIO-RSA between 2021 and 2023. Preoperative computed tomographic (CT) scans facilitated three-dimensional (3D) surgical planning. Intraoperatively, glenoid placement was guided by navigated AR. Postoperative CT scans at six months were analyzed for graft incorporation and compared with preoperative planning to assess implant positioning accuracy.

Results

The mean deviation between preoperative planning and postoperative positioning was 4.1° ± 3.4° (range, 0°–11°) in baseplate version and 1.9° ± 2.4° (range, 0°–9°) in inclination. Baseplate entry-point deviation was 1.6 mm ± 1.2 mm (range, 0.5–4.0 mm) in the antero-posterior direction and 1.1 mm ± 1.1 mm (range, 0–4.5 mm) in the superior-inferior direction. The mean deviation in baseplate offset reconstruction was 2.1 mm ± 1.6 mm (range, 0–5.5 mm). Complete graft incorporation was observed in all cases.

Conclusion

Navigated AR enhances precision in BIO-RSA, ensuring accurate correction of glenoid wear and adherence to preoperative 3D planning. Level of evidence Retrospective radiological study.

Schlagwörter

Stichwörter der Autor:innen

Reverse shoulder arthroplastyaugmented realitybony-increased offsetglenoid erosionnavigated surgeryshoulder surgery

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, AZ Sint Jan Brugge, AZ Sint-Lucas Brugge, Bruges, Belgium.

ORCID-Profile: Tanguy Segers, Joris Beckers

Zitieren

APA

Segers, T., Beckers, J., Van Isacker, T., Pierreux, P., & Berghs, B. (2026). Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series. Shoulder & Elbow, 18(6), 1322-1329. https://doi.org/10.1177/17585732261423892

Vancouver

Segers T, Beckers J, Van Isacker T, Pierreux P, Berghs B. Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series. Shoulder & Elbow. 2026;18(6):1322-1329. doi:10.1177/17585732261423892

BibTeX
@article{Segers2026,
  author = {Segers, Tanguy and Beckers, Joris and Van Isacker, Tom and Pierreux, Pieter and Berghs, Bart},
  title = {Navigated augmented reality is a valuable tool for precise glenoid component placement in angled bony augmentation reverse shoulder arthroplasty: A case series},
  journal = {Shoulder & Elbow},
  year = {2026},
  volume = {18},
  number = {6},
  pages = {1322--1329},
  doi = {10.1177/17585732261423892}
}
Kostenlos starten →