Comparison of glenoid bone grafting vs. augmented glenoid baseplates in reverse shoulder arthroplasty: a systematic review
Journal of Shoulder and Elbow Surgery · 2023-04 · 32 (4) · 885-891
DOI: 10.1016/j.jse.2022.11.017 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2023-04. Verfasst von Nathan S Lanham und 5 weiteren Autor:innen. Beteiligte Einrichtung: Columbia University Medical Center, New York, NY, USA. Hauptthemen laut MEDLINE: Shoulder Joint, Glenoid Cavity, Arthroplasty, Replacement, Shoulder. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Management of bone loss and glenoid deformity can present a significant challenge to surgeons. The purpose of this review was to compare outcomes of reverse shoulder arthroplasty (RSA) using either bone graft or augmented baseplates for the management of glenoid bone loss and deformity. METHODS: A comprehensive search of MEDLINE, Embase, and Cochrane indices was performed for studies reporting clinical outcomes following primary RSA with bone grafting or use of augmented baseplates. Pooled and frequency-weighted means, standard deviations, and ranges were calculated and reported for comparison. RESULTS: Overall, 19 studies and 652 patients with bone grafting (n = 401) and augmented baseplates (n = 251) were included in the study. Mean patient age and gender were 70.3 ± 3.1 years and 47% female in the bone grafting group and 72.9 ± 3.7 years and 59.0% female in the augmented baseplate group. Mean follow-up for the augmented baseplate group was 23.1 ± 8.2 months and 29.5 ± 10.1 months for the bone grafting group. Overall complication and revision rates were 11.7% and 4.5% for the bone grafting group and 11.8% and 3.7% for the augmented baseplate group. Range of motion as well as patient-reported and functional outcome scores were similar between both techniques. Infections, component loosening, and notching were 1.9%, 3.6%, and 24.6% in the bone grafting group and 0.7%, 1.6%, and 4.7% in the augmented baseplate group. CONCLUSIONS: Glenoid bone grafting and augmented baseplates are effective treatment options for the management of bone loss and glenoid deformity. Both treatments improve overall clinical outcomes with relatively low complication rates and revision rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Columbia University Medical Center, New York, NY, USA.
- Columbia University Medical Center, New York, NY, USA. Electronic address: cj2164@cumc.columbia.edu.
Zitieren
APA
Lanham, N. S., Peterson, J. R., Ahmed, R., Pearsall, C., Jobin, C. M., & Levine, W. N. (2023). Comparison of glenoid bone grafting vs. augmented glenoid baseplates in reverse shoulder arthroplasty: a systematic review. Journal of Shoulder and Elbow Surgery, 32(4), 885-891. https://doi.org/10.1016/j.jse.2022.11.017
Vancouver
Lanham NS, Peterson JR, Ahmed R, Pearsall C, Jobin CM, Levine WN. Comparison of glenoid bone grafting vs. augmented glenoid baseplates in reverse shoulder arthroplasty: a systematic review. Journal of Shoulder and Elbow Surgery. 2023;32(4):885-891. doi:10.1016/j.jse.2022.11.017
BibTeX
@article{Lanham2023,
author = {Lanham, Nathan S and Peterson, Joel R and Ahmed, Rifat and Pearsall, Christian and Jobin, Charles M and Levine, William N},
title = {Comparison of glenoid bone grafting vs. augmented glenoid baseplates in reverse shoulder arthroplasty: a systematic review},
journal = {Journal of Shoulder and Elbow Surgery},
year = {2023},
volume = {32},
number = {4},
pages = {885--891},
doi = {10.1016/j.jse.2022.11.017}
}
EUVIMED