EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieOpen Access · CC BY-NC 4.0

FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions

Matthew D Alexander iD, James Caldwell iD, Shane Sh Lee, Warren T Kim, Joey D English, Jaehyun Kim, Ben J McGuinness, Matthew Page, Nebiyat F Belachew iD, Jonathan A Grossberg iD, Daniel Tonetti, Jane Khalife und 8 weitere

Interventional Neuroradiology · 2026

DOI: 10.1177/15910199241284792 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Interventional Neuroradiology, 2026. Verfasst von Matthew D Alexander und 19 weiteren Autor:innen. Beteiligte Einrichtung: Neurointerventional Radiology, Sutter Medical Center Sacramento, Sacramento, CA, USA. Hauptthemen laut MEDLINE: Catheters, Infarction, Middle Cerebral Artery, Thrombectomy. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Contact aspiration mechanical thrombectomy (CAMT) with 0.088-inch catheters may improve first-pass success rates, but delivery of such catheters can be challenging and limit effectiveness. This study examines the initial multicenter experience using the FreeClimb 88 catheter paired with the Tenzing 8 delivery catheter. Materials and Methods Retrospective analysis was performed of consecutive patients with large vessel occlusion (LVO) of the internal carotid artery (ICA) or M1 segment of the middle cerebral artery treated with off-label CAMT using the FreeClimb 88 and Tenzing 8 at eight sites participating in the early limited release for these devices. Demographic and procedural variables were collected and analyzed with descriptive statistics and multivariable analysis.

Results

Fifty-three consecutive patients were treated. Large vessel occlusion was located in the ICA in 19/53 (35.8%) patients; 34/53 (64.2%) were in the M1 segment. FreeClimb 88 was successfully delivered to the site of occlusion in 50/53 (94.3%) of patients. First-pass TICI 2c or 3 was achieved with FreeClimb 88 delivered by Tenzing 8 in 36 (67.9%) cases. Among cases with successful FreeClimb 88 delivery 9/50 (18.0%) required additional smaller devices to perform thrombectomy of distal occlusions after recanalization of the initial LVO. No complications or symptomatic hemorrhages occurred following thrombectomy.

Conclusion

Contact aspiration mechanical thrombectomy performed for ICA or M1 LVOs using FreeClimb 88 delivered with Tenzing 8 was safe, effective, and efficient in this early experience, with first-pass TICI 2c or 3 was achieved in 68% of patients without procedural complications occurring in any cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CathetersInfarction, Middle Cerebral ArteryThrombectomyAgedAged, 80 and overFemaleHumansMaleMiddle AgedCerebral AngiographyEquipment DesignRetrospective StudiesTreatment Outcome

Stichwörter der Autor:innen

Mechanical thrombectomyacute strokelarge vessel occlusionsuper large bore

Autor:innen und Institutionen

  • Neurointerventional Radiology, Sutter Medical Center Sacramento, Sacramento, CA, USA.
  • Neurointerventional Radiology, Sutter Roseville Medical Center, Roseville, CA, USA.
  • Department of Radiology & Imaging Sciences, University of Utah, Salt Lake City, UT, USA.
  • Diagnostic & Interventional Neuroradiology, Auckland City Hospital, Auckland, New Zealand.
  • Neurointerventional Surgery, California Pacific Medical Center, San Francisco, CA, USA.
  • Neurointerventional Surgery, Mills-Peninsula Medical Center, Burlingame, CA, USA.

ORCID-Profile: Matthew D Alexander, James Caldwell, Nebiyat F Belachew, Jonathan A Grossberg, Omar Kass-Hout

Zitieren

APA

Alexander, M. D., Caldwell, J., Lee, S. S., Kim, W. T., English, J. D., Kim, J., McGuinness, B. J., Page, M., Belachew, N. F., Grossberg, J. A., Tonetti, D., Khalife, J., Shaikh, H., Kass-Hout, O., Colasurdo, M., Priest, R., Varjavand, B., Khangura, R. S., Chaudhry, T. A., & Settecase, F. (2026). FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions. Interventional Neuroradiology. https://doi.org/10.1177/15910199241284792

Vancouver

Alexander MD, Caldwell J, Lee SS, Kim WT, English JD, Kim J, et al. FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions. Interventional Neuroradiology. 2026. doi:10.1177/15910199241284792

BibTeX
@article{Alexander2026,
  author = {Alexander, Matthew D and Caldwell, James and Lee, Shane Sh and Kim, Warren T and English, Joey D and Kim, Jaehyun and McGuinness, Ben J and Page, Matthew and Belachew, Nebiyat F and Grossberg, Jonathan A and Tonetti, Daniel and Khalife, Jane and Shaikh, Hamza and Kass-Hout, Omar and Colasurdo, Marco and Priest, Ryan and Varjavand, Bahram and Khangura, Rajkamal S and Chaudhry, Thymur A and Settecase, Fabio},
  title = {FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions},
  journal = {Interventional Neuroradiology},
  year = {2026},
  doi = {10.1177/15910199241284792}
}
Kostenlos starten →