Mechanical thrombectomy with a new intermediate balloon catheter combining the BGC and DAC features: Initial clinical experience with the iNedit device
Interventional Neuroradiology · 2026
DOI: 10.1177/15910199231207407 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interventional Neuroradiology, 2026. Verfasst von Alejandro Tomasello und 6 weiteren Autor:innen. Beteiligte Einrichtung: Interventional Neuroradiology Section, Vall d Hebron University Hospital, Barcelona, Spain. Hauptthemen laut MEDLINE: Thrombectomy, Ischemic Stroke, Stroke. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Introduction
The iNedit balloon distal access catheter is a novel thrombectomy device. It has an inner diameter of 0.058″, proximal outer diameter of 2.13 mm, and distal outer diameter of 1.67mm. It is compatible with a 0.088″ guide catheter and includes a balloon located 5 cm from the catheter tip, enabling proximal flow restriction and combined therapy with stent retrievers. We investigate the appraisal of the use, safety, and efficacy of the iNedit catheter in the first-in-human study.
Methods
In the preliminary cases that demanded training on the product previous to a multicentric study, prospective data were collected on 22 consecutive patients treated with the iNedit catheter to perform thrombectomy for acute ischemic stroke due to large vessel occlusion within 24 h. The outcome measures consisted of several evaluations of user experience rated on a 5-point scale ranging from 1 (bad) to 5 (excellent), as well as assessments of procedural safety outcomes such as artery perforation and arterial occlusion, procedural efficacy outcomes including first-pass effect (Thrombolysis In Cerebral Infarction [TICI] 2c/3) and final recanalization (TICI 2b/3), and clinical efficacy outcomes such as a 3-month 0–2 modified Rankin Scale (mRS).
Results
The mean age was 72 ± 12 years old; median National Institute Health Stroke Scale was 17 (11–19). Sites of primary occlusion were: 2 internal carotid artery, 12 M1-MCA, 7 M2-MCA, and one P1. Median score evaluation of the appraisal of use was 4- IQR [4–5]. The median number of passes was 1 [IQR 1–2]. First pass complete recanalization rate was 50% and the final recanalization rate was 94.45%. No artery perforation and arterial occlusion. Good functional outcome mRS 0–2 was achieved in 50% of patients.
Conclusions
In this initial clinical experience, iNedit device achieved a high rate of first-pass effect and final recanalization rate with no safety concerns, thus favoring a high percentage of good clinical outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interventional Neuroradiology Section, Vall d Hebron University Hospital, Barcelona, Spain.
- Vall d'Hebron Research Institute, Vall d'Hebron Barcelona Hospital Campus, Barcelona, Spain.
- Department of Radiology, Hospital Universitario Central de Asturias, Oviedo, Spain.
- Interventional Neuroradiology Unit, University Hospital Germans Trias i Pujol, Badalona, Spain.
- Interventional Neuroradiology, Radiology Department, Hospital Clinico San Carlos, Madrid, Spain.
- Interventional Neuroradiology, Hospital General Universitario Alicante, Alicante, Spain.
ORCID-Profile: Alejandro Tomasello, Laura Ludovica Gramegna
Zitieren
APA
Tomasello, A., Gramegna, L. L., Vega, P., Castaño, C., Moreu, M., Dominguez, C., & Macho, J. (2026). Mechanical thrombectomy with a new intermediate balloon catheter combining the BGC and DAC features: Initial clinical experience with the iNedit device. Interventional Neuroradiology. https://doi.org/10.1177/15910199231207407
Vancouver
Tomasello A, Gramegna LL, Vega P, Castaño C, Moreu M, Dominguez C, et al. Mechanical thrombectomy with a new intermediate balloon catheter combining the BGC and DAC features: Initial clinical experience with the iNedit device. Interventional Neuroradiology. 2026. doi:10.1177/15910199231207407
BibTeX
@article{Tomasello2026,
author = {Tomasello, Alejandro and Gramegna, Laura Ludovica and Vega, Pedro and Castaño, Carlos and Moreu, Manuel and Dominguez, Carlos and Macho, Juan},
title = {Mechanical thrombectomy with a new intermediate balloon catheter combining the BGC and DAC features: Initial clinical experience with the iNedit device},
journal = {Interventional Neuroradiology},
year = {2026},
doi = {10.1177/15910199231207407}
}
EUVIMED