EUVIMEDEUVIMED entdecken
Crossref

Factors Associated With Chest Tube Output Following Robotic Totally Endoscopic Coronary Artery Bypass Grafting

Martin Winter iD, Syed Faaz Ashraf iD, Andrea Amabile, Neha Devineni, Kei Kobayashi, Yizhan Guo, Irsa Hasan, David Kaczorowski, Ibrahim Sultan, Johannes Bonatti

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2026-07 · 21 (4) · 340-348

DOI: 10.1177/15569845261472592 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, online erschienen am 11.08.2026. Verfasst von Martin Winter und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, UPMC Heart and Vascular Institute, PA, USA. Hauptthemen laut MEDLINE: Chest Tubes, Coronary Artery Bypass, Robotic Surgical Procedures, Endoscopy. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Data on chest tube output following robotic totally endoscopic coronary artery bypass grafting (TECAB) are limited. We aimed to quantify chest tube drainage following robotic TECAB and identify factors associated with increased output.

Methods

A total of 125 consecutive patients undergoing robotic TECAB from September 2021 to July 2025 were retrospectively analyzed. Chest tube output was recorded over 96 h postoperatively. Univariable and multivariable linear regression analyses were performed to identify predictors of increased drainage.

Results

Median chest tube output over 4 days was 945 mL (interquartile range: 703 to 1,400 mL). Median chest tube duration was 3 (2 to 4) days. Drainage volumes were lower than those reported for open coronary artery bypass grafting (CABG) and comparable with mixed robotic cardiac surgery cohorts. Increased chest tube output correlated positively with the number of transfused red blood cell units ( r s = 0.336, P < 0.001) and the number of postoperative chest radiographs ( r s = 0.378, P < 0.001). On multivariable regression analysis, age (B = 14.2 mL/year, P = 0.049), male sex (B = 353 mL, P = 0.037), and longer procedure time (B = 1.6 mL/min, P = 0.019) were independent factors associated with increased output.

Conclusions

Chest tube output after robotic TECAB appears comparable with values reported in mixed robotic cardiac surgery and lower than those reported for open CABG. Operative strategy including single versus multivessel TECAB, arrested versus beating heart, and hybrid coronary revascularization did not significantly influence output. Chest tube output after robotic TECAB was driven by age, gender, and procedure time, and higher output was associated with higher resource use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chest TubesCoronary Artery BypassRobotic Surgical ProceduresEndoscopyDrainageHumansMaleRetrospective StudiesFemaleAgedMiddle Aged

Stichwörter der Autor:innen

chest tube outputcoronary artery bypass graftingrobotic cardiac surgerytotally endoscopic coronary artery bypass grafting

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, University of Pittsburgh School of Medicine, UPMC Heart and Vascular Institute, PA, USA.

ORCID-Profile: Martin Winter, Syed Faaz Ashraf

Zitieren

APA

Winter, M., Ashraf, S. F., Amabile, A., Devineni, N., Kobayashi, K., Guo, Y., Hasan, I., Kaczorowski, D., Sultan, I., & Bonatti, J. (2026). Factors Associated With Chest Tube Output Following Robotic Totally Endoscopic Coronary Artery Bypass Grafting. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 21(4), 340-348. https://doi.org/10.1177/15569845261472592

Vancouver

Winter M, Ashraf SF, Amabile A, Devineni N, Kobayashi K, Guo Y, et al. Factors Associated With Chest Tube Output Following Robotic Totally Endoscopic Coronary Artery Bypass Grafting. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2026;21(4):340-348. doi:10.1177/15569845261472592

BibTeX
@article{Winter2026,
  author = {Winter, Martin and Ashraf, Syed Faaz and Amabile, Andrea and Devineni, Neha and Kobayashi, Kei and Guo, Yizhan and Hasan, Irsa and Kaczorowski, David and Sultan, Ibrahim and Bonatti, Johannes},
  title = {Factors Associated With Chest Tube Output Following Robotic Totally Endoscopic Coronary Artery Bypass Grafting},
  journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
  year = {2026},
  volume = {21},
  number = {4},
  pages = {340--348},
  doi = {10.1177/15569845261472592}
}
Kostenlos starten →