EUVIMEDEUVIMED entdecken
Vergleichsstudie

Routine conventional leak test is not required for robotic major pulmonary resections

Hitoshi Igai, Akinobu Ida, Kazuki Numajiri, Kazuhito Nii, Mitsuhiro Kamiyoshihara

General Thoracic and Cardiovascular Surgery · 2025

DOI: 10.1007/s11748-024-02081-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift General Thoracic and Cardiovascular Surgery, 2025. Verfasst von Hitoshi Igai und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Thoracic Surgery, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-Cho, Maebashi, Gunma, 371-0811, Japan. hitoshiigai@gmail.…. Hauptthemen laut MEDLINE: Pneumonectomy, Robotic Surgical Procedures, Drainage, Postoperative Complications. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: We retrospectively evaluated whether or not conventional air leak testing is necessary in robotic major pulmonary resections. METHODS: After excluding patients who received 2 or more days of postoperative drainage for chylothorax or excessive pleural effusion, 578 patients who underwent major pulmonary resection using minimally invasive approaches between February 2019 and November 2023 at our institution were included in this study. All patients were divided into two groups including thoracoscopic (n = 471) and robotic (n = 107) approaches. Conventional air leak testing was performed in all patients in the thoracoscopic approach but not in the robotic approach. After propensity score matching of patient backgrounds between the two groups, perioperative outcomes were compared (n = 100 each). The primary endpoint was the rate of drain removal on postoperative day (POD) 2 or later. In addition, factors associated with drain removal on POD 2 or later in the robotic group were identified. RESULTS: The rate of drain removal at POD 2 or later was not significantly different between the two groups (p = 0.011). Multivariable analysis to identify factors associated with drain removal at POD2 or later in the robotic approach showed that sealant application (p = 0.002) and lobectomy (vs. segmentectomy, p = 0.034) were significantly associated. CONCLUSIONS: In conclusion, even in the absence of air leak testing, a robotic approach for major lung resections can result in a drain removal rate on the day of surgery or POD1 that is comparable to a conventional thoracoscopic approach. However, it may be useful in selected patients requiring sealant placement or undergoing lobectomy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PneumonectomyRobotic Surgical ProceduresDrainagePostoperative ComplicationsThoracic Surgery, Video-AssistedHumansRetrospective StudiesMaleFemaleMiddle AgedAgedTreatment OutcomeRisk FactorsTime FactorsPredictive Value of TestsDevice RemovalChest Tubes

Stichwörter der Autor:innen

Air leak testLobectomyRobotSegmentectomy

Autor:innen und Institutionen

  • Department of General Thoracic Surgery, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-Cho, Maebashi, Gunma, 371-0811, Japan. hitoshiigai@gmail.com.
  • Department of General Thoracic Surgery, Japanese Red Cross Maebashi Hospital, 389-1 Asakura-Cho, Maebashi, Gunma, 371-0811, Japan.

Zitieren

APA

Igai, H., Ida, A., Numajiri, K., Nii, K., & Kamiyoshihara, M. (2025). Routine conventional leak test is not required for robotic major pulmonary resections. General Thoracic and Cardiovascular Surgery. https://doi.org/10.1007/s11748-024-02081-3

Vancouver

Igai H, Ida A, Numajiri K, Nii K, Kamiyoshihara M. Routine conventional leak test is not required for robotic major pulmonary resections. General Thoracic and Cardiovascular Surgery. 2025. doi:10.1007/s11748-024-02081-3

BibTeX
@article{Igai2025,
  author = {Igai, Hitoshi and Ida, Akinobu and Numajiri, Kazuki and Nii, Kazuhito and Kamiyoshihara, Mitsuhiro},
  title = {Routine conventional leak test is not required for robotic major pulmonary resections},
  journal = {General Thoracic and Cardiovascular Surgery},
  year = {2025},
  doi = {10.1007/s11748-024-02081-3}
}
Kostenlos starten →