EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Zero-Contrast EVAR Can Be Reached Using Automated Carbon Dioxide Digital Angiography, Endoaortic Balloon Occlusion, and IVUS

Manuel Miralles, Francesca Maria Mursia, Luis García Domínguez, Noelia Garzón, Eliseo Candela, Emma Plana iD, Sergi Bellmunt iD

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2026-07 · 21 (4) · 360-367

DOI: 10.1177/15569845261471885 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, online erschienen am 06.08.2026. Verfasst von Manuel Miralles und 6 weiteren Autor:innen. Beteiligte Einrichtung: Angiology and Vascular Surgery Service, Hospital Universitari i Politècnic La Fe, Valencia, Spain. Hauptthemen laut MEDLINE: Carbon Dioxide, Ultrasonography, Interventional, Balloon Occlusion, Endovascular Aneurysm Repair. Die Arbeit nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To introduce a new method to enhance the visualization of renal arteries and the accuracy of graft deployment during CO 2 -assisted endovascular (EV) aneurysm repair (EVAR).

Methods

A retrospective observational study of consecutive EVAR cases assisted with CO 2 angiography (CO 2 Angio) was conducted. This nonrandomized design reflects real-life progressive attempts to enhance the reliability of CO 2 and intravascular ultrasound (IVUS), minimizing the use of iodinated contrast (IC) and radiation, respectively. Cases were divided into 3 groups according to consecutive periods: CO 2 Angio ( n = 7), CO 2 Angio and balloon occlusion of the infrarenal aorta (CO 2 Angio + EVclamp, n = 11), and CO 2 Angio + EVclamp + IVUS ( n = 18). IC was permitted in case of insufficient visualization with CO 2 Angio during any phase of the procedure. Demographic, clinical, and procedure variables (volume of IC and CO 2 , radiation, fluoroscopy time, leaks) were collected from electronic clinic histories and statistically analyzed.

Results

A significant decrease was found in the third group, after introducing both techniques, for total radiation (air kerma; 3,039 ± 2,792.3 vs 3,434.7 ± 1,289.2 vs 2,284.6 ± 841.5 mGy, P = 0.041), radiation per area, dose area product (47 ± 34.7 vs 54.5 ± 15.3 vs 41.3 ± 12.8 mGy×m 2 , P = 0.03), and IC volume (104.3 ± 102.4 vs 89.2 ± 53.9 vs 15.4 ± 27.4 mL, P < 0.001), arriving at the goal of “zero contrast” in the last 12 patients. No significant differences were detected in fluoroscopy time, total operative time, total CO 2 volume, or change in renal function.

Conclusions

The introduction of endoluminal occlusion with a balloon and the use of IVUS in CO 2 -assisted EVAR enabled us to achieve the objective of zero contrast and a progressive decrease in radiation dose.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon DioxideUltrasonography, InterventionalBalloon OcclusionEndovascular Aneurysm RepairAortic Aneurysm, AbdominalEndovascular ProceduresHumansRetrospective StudiesFemaleMaleContrast MediaAgedAged, 80 and overRenal Artery

Stichwörter der Autor:innen

CO2 angiographyEVARIVUSaortaaortic balloon

Substanzen

Carbon DioxideContrast Media

Autor:innen und Institutionen

  • Angiology and Vascular Surgery Service, Hospital Universitari i Politècnic La Fe, Valencia, Spain.
  • Department of Surgery, Facultat de Medicina, Universitat de València (UV), Spain.
  • Haemostasis, Thrombosis, Arteriosclerosis and Vascular Biology Research Group, Instituto de Investigación Sanitaria La Fe (IIS La Fe), Valencia, Spain.
  • Department of Vascular Surgery, Hospital Universitari Vall d'Hebron, Barcelona, Spain.

ORCID-Profile: Emma Plana, Sergi Bellmunt

Zitieren

APA

Miralles, M., Mursia, F. M., García Domínguez, L., Garzón, N., Candela, E., Plana, E., & Bellmunt, S. (2026). Zero-Contrast EVAR Can Be Reached Using Automated Carbon Dioxide Digital Angiography, Endoaortic Balloon Occlusion, and IVUS. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 21(4), 360-367. https://doi.org/10.1177/15569845261471885

Vancouver

Miralles M, Mursia FM, García Domínguez L, Garzón N, Candela E, Plana E, et al. Zero-Contrast EVAR Can Be Reached Using Automated Carbon Dioxide Digital Angiography, Endoaortic Balloon Occlusion, and IVUS. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2026;21(4):360-367. doi:10.1177/15569845261471885

BibTeX
@article{Miralles2026,
  author = {Miralles, Manuel and Mursia, Francesca Maria and García Domínguez, Luis and Garzón, Noelia and Candela, Eliseo and Plana, Emma and Bellmunt, Sergi},
  title = {Zero-Contrast EVAR Can Be Reached Using Automated Carbon Dioxide Digital Angiography, Endoaortic Balloon Occlusion, and IVUS},
  journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
  year = {2026},
  volume = {21},
  number = {4},
  pages = {360--367},
  doi = {10.1177/15569845261471885}
}
Kostenlos starten →