Right Atrial Inflow Occlusion for Zone Zero Thoracic Endovascular Repair and Its Safety, Efficacy, and Predictors of Response
Annals of Vascular Surgery · 2025
DOI: 10.1016/j.avsg.2025.03.033 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2025. Verfasst von Wai-Yin Lai und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, The University of Hong Kong, Queen Mary Hospital, Hong Kong, China. Electronic address: gretllai@gmail.com. Hauptthemen laut MEDLINE: Endovascular Procedures, Blood Vessel Prosthesis Implantation, Balloon Occlusion, Aorta, Thoracic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Landing in the ascending aorta (zone 0) demands more precise and significant reductions of the cardiac pulsatility induced motion. Right atrial inflow occlusion with an inferior vena cava (IVC) balloon offers an alternative to traditional rapid ventricular pacing for cardiac output control during deployment of thoracic endografts. We aim to evaluate the safety and efficacy of IVC balloon occlusion and determine the predictors of the blood pressure response in patients who underwent arch-branched endovascular repair. METHODS: Consecutive patients who underwent endovascular repair of arch pathologies using custom-made inner side branch aortic endografts landing in zone 0 were studied. IVC balloon occlusion was used routinely for blood pressure reduction with a systolic target of 70 mm Hg, which is set as a balance between the risks of stent graft migration due to cardiac pulsatility-induced motion, and risks of hypotension. Primary outcomes were the safety and efficacy of IVC balloon occlusion. Secondary outcomes include the predictors of the blood pressure response during induction, deployment, and recovery phases of induced hypotension. RESULTS: A total of 23 patients were included (91.3% male, mean age 75.7 years). The median duration of IVC balloon occlusion was 60 sec (range 35-109 sec, interquartile range [IQR] 26 sec). Graft deployment took a median time of 16 sec (range 5-30 sec, IQR 16 sec). A target systolic blood pressure (SBP) lower than 70 mm Hg could be achieved in 95.7% of patients within 60 sec (with a median of 55 mm Hg). The median recovery time was 32 sec (range 25-45 sec, IQR 5 sec). A target SBP of 70 mm Hg or lower could be achieved in 95.7% of patients in our cohort with IVC balloon occlusion. All stent grafts were deployed in an accurate position. No cardiac complications or other safety issues were reported. On risk factor analysis, induction of hypotension was hastened by a lower mean intraoperative SBP (P = 0.016) which was associated with a lower preoperative SBP (P = 0.001). A shorter balloon occlusion time would lead to faster recovery of SBP (P = 0.021). CONCLUSION: IVC balloon occlusion is a simple, effective, and predictable method for reduction of aortic impulse for zone 0 thoracic endovascular repairs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Surgery, The University of Hong Kong, Queen Mary Hospital, Hong Kong, China. Electronic address: gretllai@gmail.com.
- Department of Surgery, The University of Hong Kong, Queen Mary Hospital, Hong Kong, China.
Zitieren
APA
Lai, W. Y., & Cheng, S. W. (2025). Right Atrial Inflow Occlusion for Zone Zero Thoracic Endovascular Repair and Its Safety, Efficacy, and Predictors of Response. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2025.03.033
Vancouver
Lai WY, Cheng SW. Right Atrial Inflow Occlusion for Zone Zero Thoracic Endovascular Repair and Its Safety, Efficacy, and Predictors of Response. Annals of Vascular Surgery. 2025. doi:10.1016/j.avsg.2025.03.033
BibTeX
@article{Lai2025,
author = {Lai, Wai-Yin and Cheng, Stephen Wing-Keung},
title = {Right Atrial Inflow Occlusion for Zone Zero Thoracic Endovascular Repair and Its Safety, Efficacy, and Predictors of Response},
journal = {Annals of Vascular Surgery},
year = {2025},
doi = {10.1016/j.avsg.2025.03.033}
}
EUVIMED