Dose-Gradient Function–Guided Reduction of Radiation-Induced Heart Injury in Left-Sided Breast Cancer Treated With Helical Tomotherapy After Mastectomy
Technology in Cancer Research & Treatment · 2026-06 · 25
DOI: 10.1177/15330338261454536 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technology in Cancer Research & Treatment, online erschienen am 01.06.2026. Verfasst von Yunyan Yang und 7 weiteren Autor:innen. Beteiligte Einrichtung: The Third Affiliated Hospital of Kunming Medical University, Yunnan Cancer Hospital, Peking University Cancer Hospital Yunnan, Kunming, Yunnan, China. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Unilateral Breast Neoplasms, Radiation Injuries, Heart Injuries. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Kunming Medical University Graduate Education Innovation Project, Yunnan Provincial Department of Science and Technology-Kunming Medical University Joint Special Project for Applied Basic Research.
Abstract (Originalsprache)
Introduction
Radiation-induced heart injury (RIHI) remains an important concern in left-sided postmastectomy radiotherapy (PMRT), particularly when internal mammary lymph nodes (IMLNs) are included in the target volume. Helical tomotherapy (HT) provides excellent target conformity for complex targets, but cardiac sparing remains challenging. This study evaluated whether dose-gradient function (DGF)-guided optimization could further reduce cardiac exposure in left-sided breast cancer patients treated with HT after modified radical mastectomy.
Methods
Twenty-six female patients with left-sided breast cancer who underwent PMRT were retrospectively included. Initial HT plan was generated and evaluated using DGF, which quantifies dose falloff outside the target volume. The patient with the minimum DGF curve area ( S min ) was used as the internal benchmarking and was not re-optimized. The remaining 25 patients underwent DGF-guided re-optimization. Mean heart dose (MHD), cardiac dose-volume indices, left anterior descending coronary artery (LAD) dose, and the model-based relative risk increase (RRI) of major coronary events, were compared between the original and optimized plans.
Results
DGF-guided re-optimization significantly reduced cardiac dose parameters while maintaining target coverage and overall plan quality. MHD decreased from 6.190 ± 0.384 Gy to 5.322 ± 0.332 Gy (P < 0.001), and cardiac V 5 decreased from 43.084 ± 4.807% to 29.260 ± 4.453% (P < 0.001), with significant reductions in V 10 , V 20 , and V 30 (all P < 0.05). LAD V 5 decreased from 86.150 ± 8.152% to 81.240 ± 9.100% (P < 0.001), and LAD mean dose decreased from 18.786 ± 2.661 Gy to 18.230 ± 2.691 Gy (P < 0.001). Greater cardiac dose reduction was observed in the IMLNs irradiation group. The estimated relative risk increase decreased from 45.803 ± 2.839% to 39.383 ± 2.459% (P < 0.001).
Conclusion
DGF-guided optimization may improve HT plan quality for left-sided PMRT and achieve additional reductions in cardiac dose and model-based cardiac risk estimates, particularly in cases requiring IMLNs irradiation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Third Affiliated Hospital of Kunming Medical University, Yunnan Cancer Hospital, Peking University Cancer Hospital Yunnan, Kunming, Yunnan, China.
ORCID-Profile: Yunyan Yang, Xiang Pan, Lingli Zhou, Jinli Peng, Tianwen Zhang, Yan Xu, Han Bai
Förderung
- Kunming Medical University Graduate Education Innovation Project
- Yunnan Provincial Department of Science and Technology-Kunming Medical University Joint Special Project for Applied Basic Research
Zitieren
APA
Yang, Y., Pan, X., Zhou, L., Peng, J., Zhang, T., Xu, Y., Bai, H., & Li, Y. (2026). Dose-Gradient Function–Guided Reduction of Radiation-Induced Heart Injury in Left-Sided Breast Cancer Treated With Helical Tomotherapy After Mastectomy. Technology in Cancer Research & Treatment, 25. https://doi.org/10.1177/15330338261454536
Vancouver
Yang Y, Pan X, Zhou L, Peng J, Zhang T, Xu Y, et al. Dose-Gradient Function–Guided Reduction of Radiation-Induced Heart Injury in Left-Sided Breast Cancer Treated With Helical Tomotherapy After Mastectomy. Technology in Cancer Research & Treatment. 2026;25. doi:10.1177/15330338261454536
BibTeX
@article{Yang2026,
author = {Yang, Yunyan and Pan, Xiang and Zhou, Lingli and Peng, Jinli and Zhang, Tianwen and Xu, Yan and Bai, Han and Li, Ya},
title = {Dose-Gradient Function–Guided Reduction of Radiation-Induced Heart Injury in Left-Sided Breast Cancer Treated With Helical Tomotherapy After Mastectomy},
journal = {Technology in Cancer Research & Treatment},
year = {2026},
volume = {25},
doi = {10.1177/15330338261454536}
}
EUVIMED