EUVIMEDEUVIMED entdecken
Crossref

The Varying Benefits of Two Years Automated Insulin Delivery System Use on Continuous Glucose Monitoring Profiles in Children and Adolescents with Type 1 Diabetes

Jantje Weiskorn, Marie Auzanneau, Marie-Anne Burckhardt, Nicole Blauensteiner, Ulrike Schierloh, Isa Mayer, Julia Schneidewind, Stefanie Lanzinger

Diabetes Technology & Therapeutics · 21.11.2026

DOI: 10.1177/15209156261507763 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes Technology & Therapeutics, online erschienen am 21.11.2026. Verfasst von Jantje Weiskorn und 7 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Automated insulin delivery (AID) systems are recommended for youths with type 1 diabetes, but real-world longitudinal data remains limited despite increasing use. This study evaluates the effect of 2 years of AID use on continuous glucose monitoring (CGM) profiles and body mass index (BMI) development.

Methods

Data from individuals with type 1 diabetes aged 3 months, and AID use of >3 months from the Diabetes Prospective Follow-up (DPV) Registry between 2019 and 2025 were analyzed. CGM and HbA1c were required at the last documented time in range (TIR) (±90 days; follow-up) and 2 years earlier (±90 days; baseline). Changes were investigated using adjusted regression models with repeated measurements.

Findings

Data from 2486 participants (baseline: median age: 11.9 years, diabetes duration: 5.0 years, 53% male) were analyzed over ∼23 months. The largest gains occurred in time in tight range (TiTR) (42.4% [95% confidence interval: 41.0–43.7] to 50.1% [48.8–51.4]; P < 0.001) and coefficient of variation (CV) (32.9 [32.0–33.7] to 29.5 [28.7–30.2]; P < 0.001). HbA1c (7.3% [7.2–7.3] to 7.2 [7.1–7.2]; P < 0.001), TIR (64.5% [63.9–65.1] to 66.7% [66.1–67.3]; P < 0.001), and mean sensor glucose (SG) (161.0 mg/dL [158.4–163.5] to 155.5 mg/dL [153.1–157.9]; P = 0.001) improved statistically, but below clinical relevance thresholds. Time below range (TBR) < 70 mg/dL increased (2.7% [2.6–2.9] to 3.2% [3.1–3.4]; P < 0.001), TBR < 54 mg/dL remained stable (1.7%–1.8%; P = 0.516), and severe hypoglycemia decreased (6.4–4.5/100 patient-years; P < 0.001). No changes were seen in children

Zitieren

APA

Weiskorn, J., Auzanneau, M., Burckhardt, M., Blauensteiner, N., Schierloh, U., Mayer, I., Schneidewind, J., & Lanzinger, S. (2026). The Varying Benefits of Two Years Automated Insulin Delivery System Use on Continuous Glucose Monitoring Profiles in Children and Adolescents with Type 1 Diabetes. Diabetes Technology & Therapeutics. https://doi.org/10.1177/15209156261507763

Vancouver

Weiskorn J, Auzanneau M, Burckhardt M, Blauensteiner N, Schierloh U, Mayer I, et al. The Varying Benefits of Two Years Automated Insulin Delivery System Use on Continuous Glucose Monitoring Profiles in Children and Adolescents with Type 1 Diabetes. Diabetes Technology & Therapeutics. 2026. doi:10.1177/15209156261507763

BibTeX
@article{Weiskorn2026,
  author = {Weiskorn, Jantje and Auzanneau, Marie and Burckhardt, Marie-Anne and Blauensteiner, Nicole and Schierloh, Ulrike and Mayer, Isa and Schneidewind, Julia and Lanzinger, Stefanie},
  title = {The Varying Benefits of Two Years Automated Insulin Delivery System Use on Continuous Glucose Monitoring Profiles in Children and Adolescents with Type 1 Diabetes},
  journal = {Diabetes Technology & Therapeutics},
  year = {2026},
  doi = {10.1177/15209156261507763}
}
Kostenlos starten →