EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Accuracy of Real-Time Continuous Glucose Monitoring System in Hospitalized Patients with Diabetes and Chronic Kidney Disease

Yoshinori Kakutani iD, Tomoaki Morioka iD, Shoko Miyamoto, Yuka Natsuki, Yuya Miki, Akinobu Ochi, Masanori Emoto

Diabetes Technology & Therapeutics · 01.09.2026 · 28 (9) · 958-968

DOI: 10.1177/15209156261423902 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Diabetes Technology & Therapeutics, online erschienen am 16.02.2026. Verfasst von Yoshinori Kakutani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Metabolism, Endocrinology and Molecular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan. Hauptthemen laut MEDLINE: Continuous Glucose Monitoring, Renal Insufficiency, Chronic, Blood Glucose. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Real-time continuous glucose monitoring (CGM) systems are beneficial for patients with diabetes by providing a comprehensive assessment of glycemic status and reducing hypoglycemia. However, their performance in patients with both diabetes and chronic kidney disease (CKD) during hospitalization remains unclear. This study aimed to evaluate the accuracy of real-time CGM in hospitalized patients with diabetes and CKD. Research Design and Methods: We conducted a prospective observational study including 52 patients with diabetes after excluding those with acute kidney injury, active glomerulonephritis, requiring intensive care, or undergoing hemodialysis. Participants were categorized by estimated glomerular filtration rate (eGFR, mL/min/1.73 m 2 ) into G1-2 (≥60), G3 (30–59), and G4-5 (99% of values within clinically acceptable zones.

Conclusions

The Dexcom G6 demonstrated reliable accuracy in hospitalized patients with diabetes and CKD, with better performance in advanced CKD. These findings support its clinical utility in this population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Continuous Glucose MonitoringRenal Insufficiency, ChronicBlood GlucoseHumansFemaleMaleProspective StudiesMiddle AgedHospitalizationAgedReproducibility of ResultsGlomerular Filtration RatePoint-of-Care Systems

Stichwörter der Autor:innen

CKDDexcom G6hospitalized patientsreal-time CGM

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Department of Metabolism, Endocrinology and Molecular Medicine, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.

ORCID-Profile: Yoshinori Kakutani, Tomoaki Morioka

Zitieren

APA

Kakutani, Y., Morioka, T., Miyamoto, S., Natsuki, Y., Miki, Y., Ochi, A., & Emoto, M. (2026). Accuracy of Real-Time Continuous Glucose Monitoring System in Hospitalized Patients with Diabetes and Chronic Kidney Disease. Diabetes Technology & Therapeutics, 28(9), 958-968. https://doi.org/10.1177/15209156261423902

Vancouver

Kakutani Y, Morioka T, Miyamoto S, Natsuki Y, Miki Y, Ochi A, et al. Accuracy of Real-Time Continuous Glucose Monitoring System in Hospitalized Patients with Diabetes and Chronic Kidney Disease. Diabetes Technology & Therapeutics. 2026;28(9):958-968. doi:10.1177/15209156261423902

BibTeX
@article{Kakutani2026,
  author = {Kakutani, Yoshinori and Morioka, Tomoaki and Miyamoto, Shoko and Natsuki, Yuka and Miki, Yuya and Ochi, Akinobu and Emoto, Masanori},
  title = {Accuracy of Real-Time Continuous Glucose Monitoring System in Hospitalized Patients with Diabetes and Chronic Kidney Disease},
  journal = {Diabetes Technology & Therapeutics},
  year = {2026},
  volume = {28},
  number = {9},
  pages = {958--968},
  doi = {10.1177/15209156261423902}
}
Kostenlos starten →