EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudieOpen Access · CC BY 4.0

CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial

Adam C Jowett iD, Simon J Littlewood iD, Trevor M Hodge iD, Harmeet K Dhaliwal, Jianhua Wu

Journal of Orthodontics · 2023-03 · 50 (1) · 55-68

DOI: 10.1177/14653125221118935 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Orthodontics, online erschienen am 04.09.2022. Verfasst von Adam C Jowett und 4 weiteren Autor:innen. Beteiligte Einrichtung: Orthodontic Department, Leeds Dental Institute, Leeds, UK. Hauptthemen laut MEDLINE: Orthodontic Retainers, Orthodontic Appliances, Fixed. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Services and Delivery Research Programme, CA Digital, Scheudental, Germany., Forestadent, UK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Bonded retainers are widely used to maintain the positions of anterior teeth after orthodontic treatment. Various types of bonded retainer exist however, there is a lack of evidence to indicate which type is superior.

Aim

To compare upper and lower CAD/CAM nitinol bonded retainers (Memotain ® ) with upper and lower chairside rectangular-chain bonded retainers (Ortho-FlexTech™), in terms of stability, retainer failures and patient satisfaction. Trial design: Multi-centre, two-arm, parallel-group, randomised controlled clinical trial with 1:1 allocation.

Setting

Three trial centres: University Teaching Hospital; District General Hospital; and Specialist Orthodontic Practice. All treatment was provided free as part of a state-funded healthcare system. Materials and methods: A total of 68 patients were randomly allocated to receive either upper and lower Memotain ® bonded retainers or upper and lower Ortho-FlexTech™ bonded retainers. Ten trained operators placed and reviewed the bonded retainers. Measurements were carried out on study models taken at debond and after six months. Patient satisfaction questionnaires were completed at six months following debond.

Results

The trial was terminated due to the high number of failures (50%) of the upper Memotain® retainers within six months. Memotain ® retainers were three times more likely to fail (unadjusted hazard ratio = 2.82, 95% confidence interval = 1.00-7.99) than Ortho-FlexTech™ retainers at six months in the upper arch. Patients were satisfied with both types of retainer.

Limitations

Early termination of the trial means that the a priori sample size was not reached, so outcomes should be interpreted with caution.

Conclusion

The trial was terminated early due to the high failure rate of upper Memotain ® bonded retainers. They had a higher risk of failure in the maxillary arch when compared to upper Ortho-FlexTech™ bonded retainers after six months.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic RetainersOrthodontic Appliances, FixedHumansMaxillaOrthodontic Appliance DesignAlloys

Stichwörter der Autor:innen

FailurePatient satisfactionRandomised controlled trialRetainersRetentionStability

Substanzen

nitinolAlloys

Autor:innen und Institutionen

  • Orthodontic Department, Leeds Dental Institute, Leeds, UK.
  • Orthodontic Department, St Luke's Hospital, Bradford, UK.
  • University of Leeds, School of Dentistry, Leeds, UK.

ORCID-Profile: Adam C Jowett, Simon J Littlewood, Trevor M Hodge

Förderung

  • Health Services and Delivery Research Programme
  • CA Digital, Scheudental, Germany.
  • Forestadent, UK

Zitieren

APA

Jowett, A. C., Littlewood, S. J., Hodge, T. M., Dhaliwal, H. K., & Wu, J. (2023). CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial. Journal of Orthodontics, 50(1), 55-68. https://doi.org/10.1177/14653125221118935

Vancouver

Jowett AC, Littlewood SJ, Hodge TM, Dhaliwal HK, Wu J. CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial. Journal of Orthodontics. 2023;50(1):55-68. doi:10.1177/14653125221118935

BibTeX
@article{Jowett2023,
  author = {Jowett, Adam C and Littlewood, Simon J and Hodge, Trevor M and Dhaliwal, Harmeet K and Wu, Jianhua},
  title = {CAD/CAM nitinol bonded retainer versus a chairside rectangular-chain bonded retainer: A multicentre randomised controlled trial},
  journal = {Journal of Orthodontics},
  year = {2023},
  volume = {50},
  number = {1},
  pages = {55--68},
  doi = {10.1177/14653125221118935}
}