Push-out tests and shear capacity influencing factors of PBL shear connector without concrete end-bearing effect
Advances in Structural Engineering · 06.07.2026
DOI: 10.1177/13694332261463512 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advances in Structural Engineering, online erschienen am 06.07.2026. Verfasst von Weichen Xue und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: Science and Technology Innovation Plan of Shanghai Science and Technology Commission, Key International (Regional) Joint Research Program.
Abstract (Originalsprache)
Perfobond rib shear connectors (PBLs) are largely applied in steel-concrete composite beams because they provide high shear strength, significant stiffness, and good fatigue durability. In order to clarify the respective roles of the perforating bars and concrete dowels in the shear resistance of PBLs, a total number of 42 tests were carried out on PBL push-out specimens, excluding the concrete end-bearing effect. Experimental variables comprised the concrete compressive strength, hole diameter, number and diameter of the perforating bars, and their positional arrangement within the rib holes. The test results revealed two primary failure patterns: (1) concrete slab splitting failure for specimens with one or without the perforating bar, and (2) splitting failure with transverse cracks of the concrete slab for specimens with two perforating bars. All specimens reinforced with 12 mm and 16 mm perforating bars exhibited yielding or shear failure of the bars, whereas those with 20 mm bars remained unyielded. The corresponding load-slip (P-S) curves revealed three sequential phases: an initial elastic phase, a plastic ascending phase, and a descending phase. A new predictive equation was derived through regression analysis, which has subsequently been incorporated into the Chinese design standard (GB 50917). In addition, an empirical expression for the ascending stage of the P-S curve was obtained through curve-fitting analysis.
Förderung
- Science and Technology Innovation Plan of Shanghai Science and Technology Commission
- Key International (Regional) Joint Research Program
Zitieren
APA
Xue, W., Yan, D., & Dai, Y. (2026). Push-out tests and shear capacity influencing factors of PBL shear connector without concrete end-bearing effect. Advances in Structural Engineering. https://doi.org/10.1177/13694332261463512
Vancouver
Xue W, Yan D, Dai Y. Push-out tests and shear capacity influencing factors of PBL shear connector without concrete end-bearing effect. Advances in Structural Engineering. 2026. doi:10.1177/13694332261463512
BibTeX
@article{Xue2026,
author = {Xue, Weichen and Yan, Dawei and Dai, Yan},
title = {Push-out tests and shear capacity influencing factors of PBL shear connector without concrete end-bearing effect},
journal = {Advances in Structural Engineering},
year = {2026},
doi = {10.1177/13694332261463512}
}
EUVIMED