EUVIMEDEUVIMED entdecken
Crossref

Modeling harmonic drive with small deformation of flexspline and assessment of tooth wear by sliding coefficient

Zhenjiang Yu, Siying Ling, Xiaodong Wang, Yuansong Zheng

Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology · 2023-02 · 237 (2) · 431-450

DOI: 10.1177/13506501221121930 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, online erschienen am 25.08.2022. Verfasst von Zhenjiang Yu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Natural Science Foundation Regional Joint Project through a National Natural Science Foundation of China, Liaoning Revitalization Talents Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reducing the flexspline (FS) deformation is important for decreasing the alternating stress, flare angle in the axial direction, spatial deformation of teeth, and tube length. However, it may increase the probability of insufficient engagement depth and nonexistent conjugate tooth profiles. In this study, a mathematical model of the harmonic drive (HD) with a new tooth profile is proposed to reduce the FS deformation while satisfying the engagement depth and existence of a conjugated tooth profile. First, the generation mechanism of the new tooth profile is discussed in detail and the connection method of the circular arc tooth profile and transition tooth profile in the FS were presented. Then, two key parameters of the model, the translation distance and offset distance were studied to design the ideal tooth profile. Finally, a tooth root chamfer method was proposed to achieve smooth operation of the HD. Additionally, owing to the lack of a wear assessment of the new tooth profile, a sliding coefficient calculation model was presented. To verify the feasibility of the models, a prototype with a radial deformation coefficient of 0.8 was designed, processed, and tested. The experimental results were consistent with the theoretical analyzes.

Förderung

  • National Natural Science Foundation of China
  • National Natural Science Foundation Regional Joint Project through a National Natural Science Foundation of China
  • Liaoning Revitalization Talents Program
  • National Key Research Development Program through Ministry of Science and Technology of the People’s Republic of China

Zitieren

APA

Yu, Z., Ling, S., Wang, X., & Zheng, Y. (2023). Modeling harmonic drive with small deformation of flexspline and assessment of tooth wear by sliding coefficient. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology, 237(2), 431-450. https://doi.org/10.1177/13506501221121930

Vancouver

Yu Z, Ling S, Wang X, Zheng Y. Modeling harmonic drive with small deformation of flexspline and assessment of tooth wear by sliding coefficient. Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology. 2023;237(2):431-450. doi:10.1177/13506501221121930

BibTeX
@article{Yu2023,
  author = {Yu, Zhenjiang and Ling, Siying and Wang, Xiaodong and Zheng, Yuansong},
  title = {Modeling harmonic drive with small deformation of flexspline and assessment of tooth wear by sliding coefficient},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology},
  year = {2023},
  volume = {237},
  number = {2},
  pages = {431--450},
  doi = {10.1177/13506501221121930}
}
Kostenlos starten →