Vascular access device utilization and first-attempt success rate of large-bore short peripheral catheter after anesthetic induction in perioperative general anesthesia patients
The Journal of Vascular Access · 2026-11 · 27 (6) · 2699-2705
DOI: 10.1177/11297298261468645 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Vascular Access, online erschienen am 30.07.2026. Verfasst von Lu-Jun Zhi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia Surgery Center, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
Background
The selection, placement and management of vascular access devices for surgical patients constitute a complex, multidisciplinary process. The first-attempt success rate of large-bore short peripheral catheter after anesthetic induction is a core nursing quality metric. This study investigated vascular access device utilization and the success rate in perioperative patients, providing a scientific basis for management and enhancing the quality and safety of patient care.
Methods
A retrospective observational study was conducted to collect data on surgical patients in the operating room, including vascular access device characteristics (size, number, placement site, and method), the first-attempt success rate of large-bore short peripheral catheter, intraoperative utilization and potential factors influencing the success rate. Vascular access device related complications were identified via electronic medical records review.
Results
Among 5374 patients, 75.0% (4031) of short peripheral catheters were ⩾18-gauge and brought from the ward, while 25.0% (1343) were ⩽18-gauge. The size and number of vascular access devices were sufficient to meet clinical needs. One complication was identified: postoperative extravasation. The first-attempt success rate of large-bore short peripheral catheter was 87.4%. Multivariate logistic regression analysis identified body mass index (18.5–23.9: OR = 0.102, 95% CI: 0.041–0.253; 24–27.9: OR = 0.080, 95% CI: 0.034–0.189), visible (OR = 179.547, 95% CI: 81.491–395.593), and palpable (OR = 146.922, 95% CI: 78.398–275.339) veins after tourniquet placement, and circulating nurse seniority (⩾10 years: OR = 2.252, 95% CI: 1.173–4.323) as independent factors associated with the success rate. The area under the receiver operating characteristic curve was 0.897, indicating good discriminative efficacy.
Conclusions
Current vascular access devices, predominantly short peripheral catheters, were sufficient to meet intraoperative needs. This is the first report identifying the factors associated with the first-attempt success rate of large-bore short peripheral catheter.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia Surgery Center, West China Hospital, Sichuan University, Chengdu, Sichuan Province, China.
ORCID-Profile: Lu-Jun Zhi, Fu-Rong Liu, Meng-Song Wang, Wen Yang
Zitieren
APA
Zhi, L. J., Liu, F. R., Wang, M. S., & Yang, W. (2026). Vascular access device utilization and first-attempt success rate of large-bore short peripheral catheter after anesthetic induction in perioperative general anesthesia patients. The Journal of Vascular Access, 27(6), 2699-2705. https://doi.org/10.1177/11297298261468645
Vancouver
Zhi LJ, Liu FR, Wang MS, Yang W. Vascular access device utilization and first-attempt success rate of large-bore short peripheral catheter after anesthetic induction in perioperative general anesthesia patients. The Journal of Vascular Access. 2026;27(6):2699-2705. doi:10.1177/11297298261468645
BibTeX
@article{Zhi2026,
author = {Zhi, Lu-Jun and Liu, Fu-Rong and Wang, Meng-Song and Yang, Wen},
title = {Vascular access device utilization and first-attempt success rate of large-bore short peripheral catheter after anesthetic induction in perioperative general anesthesia patients},
journal = {The Journal of Vascular Access},
year = {2026},
volume = {27},
number = {6},
pages = {2699--2705},
doi = {10.1177/11297298261468645}
}
EUVIMED