EUVIMEDEUVIMED entdecken
Vergleichsstudie

Fluoroscopy-guided catheter tip positioning optimization: 10–30 mm beyond landmarks is associated with reduced intrathoracic central venous stenosis risk in hemodialysis patients

Fen Yu iD, Liming Gan, Mei Feng, Yin Wang, Wei Xiao, Xiaomei Huang iD, Jianxin Liu

The Journal of Vascular Access · 2026

DOI: 10.1177/11297298251405368 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, 2026. Verfasst von Fen Yu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China. Hauptthemen laut MEDLINE: Cardiac Catheterization, Renal Dialysis, Constriction, Pathologic. Die Arbeit nennt 20 Literaturangaben. Gefördert von: The China Medical Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The 2019 KDOQI guidelines recommend fluoroscopy-guided placement of tunneled cuffed catheter tips within the right atrium. However, fluoroscopy may misidentify the cavoatrial junction. This study quantified the discrepancy between digital subtraction angiography and fluoroscopy in locating the cavoatrial junction and assessed its impact on intrathoracic central venous stenosis risk.

Methods

This retrospective cohort study analyzed 90 patients with right internal jugular tunneled cuffed catheters who underwent DSA at our hospital between June 2023 and May 2025; digital subtraction angiography and fluoroscopy were compared in locating the cavoatrial junction. Catheter tips were classified by DSA-defined location: superior vena cava upper segment (Group A), lower segment (Group B), or right atrium (Group C). Intrathoracic central venous stenosis risks were analyzed using logistic regression.

Results

The DSA-defined cavoatrial junction was consistently 21.64 ± 7.23 mm caudal to fluoroscopic landmarks. The incidence of central venous stenosis was 34.4%. Intrathoracic central venous stenosis incidence was significantly higher in Group A versus C ( p < 0.0167) and Group B versus C ( p < 0.0167). Catheter tip location within the superior vena cava was associated with 5.78-fold higher odds of intrathoracic central venous stenosis compared to placement within the right atrium (OR = 5.78, 95% CI: 1.75–19.06; p = 0.004).

Conclusion

Fluoroscopy overestimates the cavoatrial junction position. Given that right atrium placement reduces intrathoracic central venous stenosis risk, advancing the catheter tip 10–30 mm beyond fluoroscopically guided landmarks constitutes a key maneuver for achieving accurate positioning. Implementation of this optimization strategy is associated with a 5.78-fold reduction in odds of intrathoracic central venous stenosis, providing actionable optimization for hemodialysis access management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac CatheterizationRenal DialysisConstriction, PathologicRetrospective StudiesHumansFluoroscopyAngiography, Digital SubtractionMaleFemaleAdultMiddle AgedAgedAged, 80 and overRisk FactorsAnatomic Landmarks

Stichwörter der Autor:innen

Intrathoracic central venous stenosisangiographycavoatrial junctionfluoroscopyrisk factors

Autor:innen und Institutionen

  • Department of Ultrasound, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Department of Chronic Disease Management Center, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Department of Nephrology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.

ORCID-Profile: Fen Yu, Xiaomei Huang

Förderung

  • The China Medical Foundation

Zitieren

APA

Yu, F., Gan, L., Feng, M., Wang, Y., Xiao, W., Huang, X., & Liu, J. (2026). Fluoroscopy-guided catheter tip positioning optimization: 10–30 mm beyond landmarks is associated with reduced intrathoracic central venous stenosis risk in hemodialysis patients. The Journal of Vascular Access. https://doi.org/10.1177/11297298251405368

Vancouver

Yu F, Gan L, Feng M, Wang Y, Xiao W, Huang X, et al. Fluoroscopy-guided catheter tip positioning optimization: 10–30 mm beyond landmarks is associated with reduced intrathoracic central venous stenosis risk in hemodialysis patients. The Journal of Vascular Access. 2026. doi:10.1177/11297298251405368

BibTeX
@article{Yu2026,
  author = {Yu, Fen and Gan, Liming and Feng, Mei and Wang, Yin and Xiao, Wei and Huang, Xiaomei and Liu, Jianxin},
  title = {Fluoroscopy-guided catheter tip positioning optimization: 10–30 mm beyond landmarks is associated with reduced intrathoracic central venous stenosis risk in hemodialysis patients},
  journal = {The Journal of Vascular Access},
  year = {2026},
  doi = {10.1177/11297298251405368}
}
Kostenlos starten →