Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland
European Journal of Vascular and Endovascular Surgery · 2025
DOI: 10.1016/j.ejvs.2025.11.058 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2025. Verfasst von Jouni Laurén und 10 weiteren Autor:innen. Beteiligte Einrichtung: HUS Diagnostic Centre, Radiology, Helsinki University and Helsinki University Hospital, Helsinki, Uusimaa, Finland. Electronic address: jouni.lauren@…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Endovascular Aneurysm Repair, Radiation Dosage, Radiation Exposure. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVE: Endovascular aneurysm repair (EVAR) predisposes patients to significant radiation exposure, with well known harmful effects. This study aimed to assess the radiation doses and their consistency in Finland and to investigate the factors affecting the doses, to potentially allow future dose reductions. METHODS: This retrospective, nationwide, multicentre study included all patients who underwent an elective standard EVAR procedure in Finland between 2017 - 2022. Data were collected from: body mass index (BMI); fluoroscopy time (FT); radiation exposure, including kerma area product (KAP) and cumulative air kerma at the patient reference entrance point (Ka,r) from fluoroscopy and digital subtraction angiography (DSA); number of DSA series; and exposure parameters of the angiography systems. Descriptive statistics and linear regression analyses were performed to identify the parameters that significantly influenced radiation exposure. RESULTS: From all five centres that perform EVAR in Finland 1 185 EVAR procedures were included. Large variation in medians of total procedure KAP between the centres was observed, ranging 22.5 - 135.0 Gy·cm2. Median FT ranged 16.1 - 29.1 minutes. Both fluoroscopy and DSA showed large variation in radiation exposure. BMI did not significantly differ between the centres. The factors significantly affecting the dose in the multivariable linear regression model were BMI, FT, number of DSA acquisitions, DSA frame rate, and maximum copper filtration in fluoroscopy. CONCLUSION: Surprisingly high, up to six fold, between centre variability in total procedure radiation exposure was observed. The variability in the doses was mostly attributable to differences in exposure parameters (e.g., dose at detector level, copper filtration, and pulse rate); the manner in which radiation is used also played a significant role. In other words, both angiography system parameters and the working habits of the operator need to be optimised.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- HUS Diagnostic Centre, Radiology, Helsinki University and Helsinki University Hospital, Helsinki, Uusimaa, Finland. Electronic address: jouni.lauren@hus.fi.
- HUS Diagnostic Centre, Radiology, Helsinki University and Helsinki University Hospital, Helsinki, Uusimaa, Finland.
- Department of Vascular Surgery, Turku University Hospital, Turku, Finland.
- Centre for Vascular Surgery and Interventional Radiology, Tampere University Hospital, and Tampere University, Faculty of Medicine and Life Sciences, Tampere, Finland.
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland; Department of Medical Physics, Medical Imaging Centre, Tampere University Hospital, Tampere, Finland; Department of Radiology, Medical Ima…
- Department of Vascular Surgery, Heart Centre, Kuopio University Hospital, Kuopio, Finland.
Zitieren
APA
Laurén, J., Kaasalainen, T., Kesävuori, R., Nikulainen, V., Suominen, V., Hakulinen, U., Karjalainen, J., Kariniemi, J., Venermo, M., Aho, P., & Finnish Radiation Safety Collaboration Group (2025). Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2025.11.058
Vancouver
Laurén J, Kaasalainen T, Kesävuori R, Nikulainen V, Suominen V, Hakulinen U, et al. Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland. European Journal of Vascular and Endovascular Surgery. 2025. doi:10.1016/j.ejvs.2025.11.058
BibTeX
@article{Laurn2025,
author = {Laurén, Jouni and Kaasalainen, Touko and Kesävuori, Risto and Nikulainen, Veikko and Suominen, Velipekka and Hakulinen, Ullamari and Karjalainen, Jari and Kariniemi, Juho and Venermo, Maarit and Aho, Pekka and Finnish Radiation Safety Collaboration Group, Finnish Radiation Safety Collaboration Group},
title = {Radiation Exposure during Elective Endovascular Abdominal Aortic Aneurysm Repair: A Nationwide Study of Patient Doses in Finland},
journal = {European Journal of Vascular and Endovascular Surgery},
year = {2025},
doi = {10.1016/j.ejvs.2025.11.058}
}
EUVIMED