IC-ECG guided PICC tip location in a dextrocardia: A case report
The Journal of Vascular Access · 2025
DOI: 10.1177/11297298241278384 ↗Kurz gefasst
Fallbericht in der Zeitschrift The Journal of Vascular Access, 2025. Verfasst von Weiru Qiao und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Surgery, Tangdu Hospital of Air Force Medical University, Xi'an, China. Hauptthemen laut MEDLINE: Dextrocardia, Electrocardiography, Catheterization, Peripheral, Catheterization, Central Venous. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: Tangdu Innovative Development Project.
Abstract (Originalsprache)
Introduction
Mirror people have difficulty with PICC placement due to inversion of organs. Intracavitary electrocardiography (IC-ECG) guided peripherally inserted central catheter (PICC) tip location technique has been widely applied in clinical practice. Case description: Herein, we admitted a 59-year-old man diagnosed with esophageal cancer (EC). Chest X-ray and computed tomography (CT) revealed that the patient was with a mirror-image dextrocardia and situs inversus totalis: the heart and stomach located in the right side of the body, whereas the liver located in the left side. Echocardiography suggested that the apex of the heart pointed toward the right, while the left and right chambers were inverted. The relationship of the heart chambers, structure, and function were normal: left ventricular ejection fraction was 0.67, left atrial diameter was 31 mm, and heart output was 4.7 L/min. Surface ECG showed typical features of a dextrocardia: P-wave inverted on lead I. Amplitude of the R-wave and S-wave decreased gradually on lead chest from V1 to V5. Compared with the normal ECG image, the waves completely exchanged on lead II and III, so as on aVR and aVL.
Methods
Column of saline technique can assist operator estimate the tip position in real-time according to P-wave changes. When the height of P-wave reaches to its highest, it means that the tip of catheter has advanced to the target position of cavo-atrial junction (CAJ). Outcomes: Patient was inserted catheter and no adverse events were reported.
Conclusions
Measuring the predicted length of catheter is still an indispensible procedure to help precisely adjusting the tip position in IC-ECG guided PICC. Our work provides both supplement for clinical data to facilitate further research and better understanding of special types of PICC to clinicians.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Thoracic Surgery, Tangdu Hospital of Air Force Medical University, Xi'an, China.
- Department of Orthopedics, Xianyang First People's Hospital, Xianyang, China.
- Department of Cardiology, Tangdu Hospital of Air Force Medical University, Xi'an, China.
ORCID-Profile: Dongdong Li, Xiaolong Yan
Förderung
- Tangdu Innovative Development Project
Zitieren
APA
Qiao, W., Qiao, L., Li, D., Wang, Y., Ren, Y., Liu, Q., Wang, Y., Li, Y., Wang, D., Lv, F., Wu, R., Shi, Y., Hou, L., & Yan, X. (2025). IC-ECG guided PICC tip location in a dextrocardia: A case report. The Journal of Vascular Access. https://doi.org/10.1177/11297298241278384
Vancouver
Qiao W, Qiao L, Li D, Wang Y, Ren Y, Liu Q, et al. IC-ECG guided PICC tip location in a dextrocardia: A case report. The Journal of Vascular Access. 2025. doi:10.1177/11297298241278384
BibTeX
@article{Qiao2025,
author = {Qiao, Weiru and Qiao, Liping and Li, Dongdong and Wang, Yuanyong and Ren, Yaru and Liu, Qiao and Wang, Ying and Li, Yufang and Wang, Dongdong and Lv, Feifei and Wu, Rong and Shi, Yuan and Hou, Lihua and Yan, Xiaolong},
title = {IC-ECG guided PICC tip location in a dextrocardia: A case report},
journal = {The Journal of Vascular Access},
year = {2025},
doi = {10.1177/11297298241278384}
}
EUVIMED