EUVIMEDEUVIMED entdecken
VergleichsstudieBeobachtungsstudie

Comparison of clinical examination, doppler and fistulogram for arterio-venous fistula surveillance in detecting secondary failure

Manoj Prabhakaran iD, Himansu Sekhar Mahapatra iD, Ranjith Kumar Nath iD, Lalit Pursnani, Muthukumar Balakrishnan, Anamika Singh, Amandeep Singh, Sanket Patil, Abhisek Gautam

The Journal of Vascular Access · 2024-09 · 25 (5) · 1567-1575

DOI: 10.1177/11297298231161461 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Vascular Access, online erschienen am 15.06.2023. Verfasst von Manoj Prabhakaran und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology, ABVIMS, Dr. Ram Manohar Lohia Hospital, New Delhi, India. Hauptthemen laut MEDLINE: Arteriovenous Shunt, Surgical, Renal Dialysis, Predictive Value of Tests, Treatment Failure. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Arteriovenous Fistula (AVF) surveillance is required to detect early dysfunction (thrombosis, stenosis) and its timely correction prolongs access-patency. Clinical examination (CE) and doppler have been used as screening/surveillance of AVF, for early detection of AVF dysfunction. Since there was inadequate evidence for KDOQI to make recommendations on AVF surveillance and on secondary failure rate. We compared CE, doppler and fistulogram as surveillance modalities in detecting a secondary failure in matured AVF. Methodology: This prospective-observational, single-center study, was done between December 2019-April 2021. CKD stage 5 patients on dialysis/Not-on-dialysis with matured AVF were included at third month. CE, doppler (blood flow, vein diameter, depth), and fistulogram were done at third and sixth month. Secondary failure was assessed at sixth month classifying AVF to patent/functional and failed group. Diagnostic tests were performed by comparing three methods considering fistulogram as gold-standard. Residual urine output is also monitored to look for any contrast induced residual renal function loss.

Results

Of total 407 created AVF, 98 (24%) had primary failure. Twenty-five (6%) had surgical complications including unsuccessful AVF and aneurysm/rupture, 156 lost follow-up at third month, 104 consented patients were enrolled, 16 lost to follow-up subsequently, and 88 patients’ data were analyzed at the end. At the sixth month, 76(86.4%) had patent AVF, 8 (9.1%) had secondary failure (Thrombosis-4, Central Venous Stenosis-4), and 4 (4.1%) patients expired. Considering fistulogram as a diagnostic standard, CE showed 87.5% sensitivity, and 93.4% specificity (cohen’s kappa value of 0.66). Doppler had sensitivity and specificity of 87% and 96% respectively (cohen’s kappa value of 0.75), Combination of clinical examination with doppler showed sensitivity and specificity of 100% and 89% respectively.

Conclusion

Although the secondary AVF failure rate is less than the primary, CE is an important and valuable tool in the diagnosis and surveillance of AVF in detecting its dysfunction. Moreover, CE with doppler can be used as a surveillance protocol that can detect early AVF dysfunction at par with Fistulogram.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arteriovenous Shunt, SurgicalRenal DialysisPredictive Value of TestsTreatment FailureVascular PatencyGraft Occlusion, VascularUltrasonography, DopplerHumansMaleProspective StudiesMiddle AgedFemaleTime FactorsAgedAdultRegional Blood FlowReproducibility of ResultsPhysical ExaminationBlood Flow Velocity

Stichwörter der Autor:innen

AVFDialysis accessfistulogramsecondary failuresurveillance

Autor:innen und Institutionen

  • Department of Nephrology, ABVIMS, Dr. Ram Manohar Lohia Hospital, New Delhi, India.
  • Department of Cardiology, ABVIMS, Dr. Ram Manohar Lohia Hospital, New Delhi, India.

ORCID-Profile: Manoj Prabhakaran, Himansu Sekhar Mahapatra, Ranjith Kumar Nath

Zitieren

APA

Prabhakaran, M., Mahapatra, H. S., Nath, R. K., Pursnani, L., Balakrishnan, M., Singh, A., Singh, A., Patil, S., & Gautam, A. (2024). Comparison of clinical examination, doppler and fistulogram for arterio-venous fistula surveillance in detecting secondary failure. The Journal of Vascular Access, 25(5), 1567-1575. https://doi.org/10.1177/11297298231161461

Vancouver

Prabhakaran M, Mahapatra HS, Nath RK, Pursnani L, Balakrishnan M, Singh A, et al. Comparison of clinical examination, doppler and fistulogram for arterio-venous fistula surveillance in detecting secondary failure. The Journal of Vascular Access. 2024;25(5):1567-1575. doi:10.1177/11297298231161461

BibTeX
@article{Prabhakaran2024,
  author = {Prabhakaran, Manoj and Mahapatra, Himansu Sekhar and Nath, Ranjith Kumar and Pursnani, Lalit and Balakrishnan, Muthukumar and Singh, Anamika and Singh, Amandeep and Patil, Sanket and Gautam, Abhisek},
  title = {Comparison of clinical examination, doppler and fistulogram for arterio-venous fistula surveillance in detecting secondary failure},
  journal = {The Journal of Vascular Access},
  year = {2024},
  volume = {25},
  number = {5},
  pages = {1567--1575},
  doi = {10.1177/11297298231161461}
}
Kostenlos starten →