EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

A haemodialysis catheter misplaced due to central venous stenosis: a case report

Xuejiao Jia, Xiaodong Li

Journal of the Pakistan Medical Association · 2024

DOI: 10.47391/jpma.10163 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of the Pakistan Medical Association, 2024. Verfasst von Xuejiao Jia und 1 weiteren Autor:innen. Beteiligte Einrichtung: Science and Education Department, Baoding No. 1, Central Hospital, Baoding, China. Hauptthemen laut MEDLINE: Renal Dialysis, Catheterization, Central Venous, Jugular Veins, Kidney Failure, Chronic. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chronic kidney disease has become a significant global health issue, with some individuals progressing to end-stage renal disease (ESRD) and requiring renal replacement therapy. For ESRD patients undergoing haemodialysis, the first step is to establish vascular access. In emergency situations, inserting a haemodialysis catheter (HDC) into the central vein is often the most appropriate approach; the right internal jugular vein (IJV) is considered the optimal site for catheterisation. However, catheter placement in the right IJV can sometimes lead to inadvertent entry into an abnormal position. Herein, we present a unique case in which the tip of the HDC was noted to have misplaced into the left IJV due to the patient's multiple central venous stenosis (CVS). This case highlights the clinical manifestation of HDC misplacement, with CVS being the underlying cause. Therefore, healthcare providers should pay adequate attention to CVS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisCatheterization, Central VenousJugular VeinsKidney Failure, ChronicHumansConstriction, PathologicCentral Venous CathetersMaleMiddle AgedCatheters, Indwelling

Stichwörter der Autor:innen

Chronic kidney disease, Haemodialysis, Internal jugular vein, Central venous st…

Autor:innen und Institutionen

  • Science and Education Department, Baoding No. 1, Central Hospital, Baoding, China.
  • Department of Nephrology, Baoding No. 1 Central Hospital, Baoding, China.

Zitieren

APA

Jia, X., & Li, X. (2024). A haemodialysis catheter misplaced due to central venous stenosis: a case report. Journal of the Pakistan Medical Association. https://doi.org/10.47391/jpma.10163

Vancouver

Jia X, Li X. A haemodialysis catheter misplaced due to central venous stenosis: a case report. Journal of the Pakistan Medical Association. 2024. doi:10.47391/jpma.10163

BibTeX
@article{Jia2024,
  author = {Jia, Xuejiao and Li, Xiaodong},
  title = {A haemodialysis catheter misplaced due to central venous stenosis: a case report},
  journal = {Journal of the Pakistan Medical Association},
  year = {2024},
  doi = {10.47391/jpma.10163}
}