Diagnostic accuracy of imaging techniques for aseptic loosening in total hip arthroplasty; a systematic review
HIP International · 18.11.2026
DOI: 10.1177/11207000261491642 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift HIP International, online erschienen am 18.11.2026. Verfasst von Alon G M Hopman und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery and Sports Medicine, Amsterdam UMC, Location University of Amsterdam, Amsterdam, The Netherlands. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Fund for Regional Development (EFRO), European Union.
Abstract (Originalsprache)
Background
As the number of total hip arthroplasties (THAs) performed worldwide increases, the burden of revision surgery rises, with aseptic loosening being a leading cause. Diagnostic imaging strategies remain suboptimal, potentially leading to unnecessary revision or undertreatment. This systematic review aimed to compare the diagnostic accuracy of imaging modalities for detecting aseptic loosening in THA, using intraoperative findings as the reference standard.
Methods
This PRISMA-compliant systematic review included a search in PubMed, Embase, and the Cochrane Library. Eligible studies included adult patients with suspected aseptic loosening of THA, comparing at least one imaging modality to the intraoperative finding. Risk of bias was assessed using the QUADAS-2 tool. Diagnostic performance metrics were extracted or calculated.
Results
The search and selection yielded 11 articles. Imaging modalities included plain radiography, CT-scans, SPECT/CT, FDG-PET, bone scintigraphy, arthrography, and MRI. Risk of bias was high in all studies, primarily related to patient selection and applicability of the reference standard. The overall certainty of evidence ranged from low to moderate. Dual-energy CT and inducible motion CT showed the highest reported diagnostic performance, based on single-centre studies.
Conclusions
All included studies demonstrated a high risk of bias, and surgeons were not blinded at the time of revision surgery. As a result, no reliable diagnostic strategy can currently be recommended. The favorable findings for CT-based techniques are hypothesis-generating. Methodologically robust, double-blinded studies are required to determine the true accuracy of advanced imaging techniques. PROSPERO registration number: CRD42024584480
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery and Sports Medicine, Amsterdam UMC, Location University of Amsterdam, Amsterdam, The Netherlands.
- Amsterdam Movement Sciences, Sports, Musculoskeletal Health, Amsterdam, The Netherlands.
- Amsterdam University Medical Centre, Faculty of Medicine, University of Amsterdam, The Netherlands.
- Department of Orthopaedic Surgery, Xpert Clinics, Amsterdam, The Netherlands.
- Spaarnegasthuis Academy, Department of Orthopedic Surgery, Hoofddorp, The Netherlands.
- Centre for Orthopedic Research Alkmaar (CORAL), Alkmaar, The Netherlands; Department of Orthopaedic Surgery, NorthWest Clinics, Alkmaar, The Netherlands.
ORCID-Profile: Alon G M Hopman
Förderung
- European Fund for Regional Development (EFRO), European Union
Zitieren
APA
Hopman, A. G. M., Blankevoort, L., Van Alebeek, E. H. J., Sierevelt, I. N., Temmerman, O. P. P., Jamaludin, F. S., Schafroth, M. U., & Kievit, A. J. (2026). Diagnostic accuracy of imaging techniques for aseptic loosening in total hip arthroplasty; a systematic review. HIP International. https://doi.org/10.1177/11207000261491642
Vancouver
Hopman AGM, Blankevoort L, Van Alebeek EHJ, Sierevelt IN, Temmerman OPP, Jamaludin FS, et al. Diagnostic accuracy of imaging techniques for aseptic loosening in total hip arthroplasty; a systematic review. HIP International. 2026. doi:10.1177/11207000261491642
BibTeX
@article{Hopman2026,
author = {Hopman, Alon G M and Blankevoort, Leendert and Van Alebeek, Esmee H J and Sierevelt, Inger N and Temmerman, Olivier P P and Jamaludin, Faridi S and Schafroth, Matthias U and Kievit, Arthur J},
title = {Diagnostic accuracy of imaging techniques for aseptic loosening in total hip arthroplasty; a systematic review},
journal = {HIP International},
year = {2026},
doi = {10.1177/11207000261491642}
}
EUVIMED