Fachartikel in der Zeitschrift European Journal of Ophthalmology, 2026. Verfasst von Luis Fernández-Vega-Cueto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. Hauptthemen laut MEDLINE: Visual Acuity, Multifocal Intraocular Lenses, Refraction, Ocular, Lens Implantation, Intraocular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
Purpose
To optically characterize and clinically evaluate the new trifocal AT ELANA 841P intraocular lens (IOL).
Methods
The optical imaging performance was assessed using an on-bench model eye through the Through-Focus Modulation Transfer Function Area (TF-MTFa) from +1.00 to −3.50D. The clinical study included manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, distance-corrected intermediate (DCIVA) and near visual acuity (DCNVA), binocular photopic and mesopic contrast sensitivity (CS) and binocular defocus curve. Postoperative evaluation was performed 3 months after surgery.
Results
Optimal optical quality is observed at the distance focus on the TF-MTFa curve. From there, optical quality continuously degrades, initially rapid up to approximately −0.75D, then much slower extending to −2.0D. Subsequently, optical quality improves before a decline from −2.75D. The clinical study involved 40 patients. The mean postoperative monocular UDVA and CDVA were 0.04 ± 0.05 and 0.01 ± 0.02 logMAR, respectively. All eyes achieved a monocular UDVA of 0.2 logMAR or better and a monocular CDVA of 0.1 logMAR or better. All patients reached a binocular DCNVA of 0.2 logMAR or better, and 95% achieved a DCIVA of 0.2 logMAR or better. The defocus curve yielded a range from +0.50 to −2.5D, in which the mean visual acuity was 0.1 logMAR or better. The binocular distance CS was within normal limits.
Conclusions
The implantation of the new AT ELANA IOL provided a satisfactory range of visual quality from distance to near, in excellent agreement with the IOL optical performance obtained with the on-bench model eye.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fernández-Vega Ophthalmological Institute, Oviedo, Spain.
- Applied Optics and Image Processing Research Group (GOAPI), Department of Optics and Optometry, Universitat Politècnica de Catalunya BarcelonaTech, Terrassa, Spain.
- Clinical and Experimental Eye Research (CEER), Optometry and Vision Department, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain.
ORCID-Profile: Luis Fernández-Vega-Cueto, Fidel Vega, David Madrid-Costa, José F Alfonso
Zitieren
APA
Fernández-Vega-Cueto, L., Alfonso-Bartolozzi, B., Lisa, C., Vega, F., Millán, M. S., Madrid-Costa, D., & Alfonso, J. F. (2026). Optical and clinical outcomes of a new diffractive trifocal intraocular lens. European Journal of Ophthalmology. https://doi.org/10.1177/11206721251387374
Vancouver
Fernández-Vega-Cueto L, Alfonso-Bartolozzi B, Lisa C, Vega F, Millán MS, Madrid-Costa D, et al. Optical and clinical outcomes of a new diffractive trifocal intraocular lens. European Journal of Ophthalmology. 2026. doi:10.1177/11206721251387374
BibTeX
@article{FernndezVegaCueto2026,
author = {Fernández-Vega-Cueto, Luis and Alfonso-Bartolozzi, Belén and Lisa, Carlos and Vega, Fidel and Millán, María S and Madrid-Costa, David and Alfonso, José F},
title = {Optical and clinical outcomes of a new diffractive trifocal intraocular lens},
journal = {European Journal of Ophthalmology},
year = {2026},
doi = {10.1177/11206721251387374}
}
EUVIMED