EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY-NC 4.0

Clinical Outcomes after Implantation of a Novel Binocular Complementary Extended Depth-of-Focus Intraocular Lens Compared to Bilateral Low Near-Add Multifocal Intraocular Lenses

Hannah Ivellio-Vellin, Manuel Ruiss, Julius Hienert, Stefan Georgiev, Caroline Pilwachs, Andreea Fisus, Oliver Findl

Ophthalmic Research · 10.09.2024 · 67 (1) · 549-557

DOI: 10.1159/000541308 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Ophthalmic Research, online erschienen am 10.09.2024. Verfasst von Hannah Ivellio-Vellin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. Hauptthemen laut MEDLINE: Visual Acuity, Vision, Binocular, Multifocal Intraocular Lenses, Contrast Sensitivity. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Nowadays, patients expect to be less spectacle dependent at all distances after cataract surgery. However, all intraocular lens (IOL) models that currently offer this function can also have negative visual effects. Aim of this study was therefore to compare the visual function performance of a novel and a conventional IOL solution for multifocality.

Methods

Patients scheduled for bilateral cataract surgery were randomized to receive one of two different IOL combinations: either a binocular complementary extended depth-of-focus IOL set or a low near-add MIOL. Patients had visual acuity (VA) assessment at distance, intermediate, and near as well as evaluation of contrast sensitivity, halometry, and reading performance.

Results

In total, 56 eyes of 28 patients were enrolled. At 6 months, there were no statistically significant differences in binocular VA between the ARTIS SYMBIOSE and the AT LARA. Contrast sensitivity, measured binocularly, at 1.5 cycles per degree under photopic conditions without glare was 1.54 logCS with the ARTIS SYMBIOSE and 1.43 logCS with the AT LARA (p = 0.046), under mesopic conditions with glare at 1.5 and 3 cycles per degree 1.31 logCS and 1.28 logCS with the ARTIS SYMBIOSE, respectively, compared to 0.58 logCS and 0.51 logCS with the AT LARA (p = 0.002; p = 0.006). Binocular halos and reading performance between both groups were similar.

Conclusion

There were no significant differences between both groups in VA at different distances, reading ability, or halometry. The contrast sensitivity at low spatial frequencies was better in the ARTIS SYMBIOSE group under photopic conditions without glare as well as mesopic conditions with glare, which could potentially improve quality of vision with these IOLs, especially under mesopic conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityVision, BinocularMultifocal Intraocular LensesContrast SensitivityProsthesis DesignHumansFemaleMaleAgedMiddle AgedLens Implantation, IntraocularDepth PerceptionProspective StudiesPhacoemulsificationPseudophakiaLenses, IntraocularAged, 80 and overFollow-Up StudiesRefraction, Ocular

Stichwörter der Autor:innen

Cataract surgeryPresbyopia correctionRandomized clinical trial

Autor:innen und Institutionen

  • Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria.

Zitieren

APA

Ivellio-Vellin, H., Ruiss, M., Hienert, J., Georgiev, S., Pilwachs, C., Fisus, A., & Findl, O. (2024). Clinical Outcomes after Implantation of a Novel Binocular Complementary Extended Depth-of-Focus Intraocular Lens Compared to Bilateral Low Near-Add Multifocal Intraocular Lenses. Ophthalmic Research, 67(1), 549-557. https://doi.org/10.1159/000541308

Vancouver

Ivellio-Vellin H, Ruiss M, Hienert J, Georgiev S, Pilwachs C, Fisus A, et al. Clinical Outcomes after Implantation of a Novel Binocular Complementary Extended Depth-of-Focus Intraocular Lens Compared to Bilateral Low Near-Add Multifocal Intraocular Lenses. Ophthalmic Research. 2024;67(1):549-557. doi:10.1159/000541308

BibTeX
@article{IvellioVellin2024,
  author = {Ivellio-Vellin, Hannah and Ruiss, Manuel and Hienert, Julius and Georgiev, Stefan and Pilwachs, Caroline and Fisus, Andreea and Findl, Oliver},
  title = {Clinical Outcomes after Implantation of a Novel Binocular Complementary Extended Depth-of-Focus Intraocular Lens Compared to Bilateral Low Near-Add Multifocal Intraocular Lenses},
  journal = {Ophthalmic Research},
  year = {2024},
  volume = {67},
  number = {1},
  pages = {549--557},
  doi = {10.1159/000541308}
}
Kostenlos starten →