EUVIMEDEUVIMED entdecken
Fallbericht

Removal of aqueous humor and conjunctival compression sutures for a dysesthesic filtering bleb: A surgical technique and case report

Elena Arias-García iD, Cristina Martinez-Gil iD, Marc Bautista-Cortiella, Gonzalo Roig-Ferreruela iD, Jose Vicente Piá-Ludeña iD, Aitor Lanzagorta-Aresti

European Journal of Ophthalmology · 2025

DOI: 10.1177/11206721241304157 ↗

Kurz gefasst

Fallbericht in der Zeitschrift European Journal of Ophthalmology, 2025. Verfasst von Elena Arias-García und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Department, Fundación Oftalmológica Médica de la Comunidad Valenciana (FOM), Valencia, Spain. Hauptthemen laut MEDLINE: Glaucoma Drainage Implants, Suture Techniques, Aqueous Humor, Conjunctiva. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

To present a novel surgical technique for the treatment of a steep-walled filtering bleb following an Ahmed glaucoma valve implant. The primary aim was to alleviate the patient's discomfort and address associated corneal thinning, complications that can arise from this condition.

Methods

Case report and surgical technique. This case report describes a 29-year-old female who developed a dysesthesic filtering bleb following the implantation of a glaucoma drainage device. The employed surgical technique to address this complication involved the drainage of aqueous from the bleb using a 30-G needle, which effectively reduced its height. Subsequently, a compression suture was applied to maintain an appropriate bleb size.

Results

With the presented surgical technique, the ultimate control of an overhigh filtering bleb associated to a glaucoma drainage device was possible. Following the procedure, the patient's symptoms and the corneal thinning linked to the bleb's excessive size were successfully managed. Furthermore, the anatomy of the filtering bleb was preserved, and an optimal intraocular pressure outcome was achieved.

Conclusions

The removal of aqueous and the application of a compression suture are two surgical techniques traditionally used for managing the hypertensive phase of glaucoma drainage devices and for alleviating discomfort from blebs after classical filtering surgery, respectively. In the case presented, the combination of these two techniques effectively reduced the size of an excessively high filtering bleb associated with a glaucoma drainage device. This approach successfully resolved the patient's discomfort and corneal issues related to this complication.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glaucoma Drainage ImplantsSuture TechniquesAqueous HumorConjunctivaGlaucomaSuturesFiltering SurgeryBlisterPostoperative ComplicationsHumansFemaleAdultIntraocular Pressure

Stichwörter der Autor:innen

GLAUCOMAangle closureaqueous humor dynamicsdiagnostic techniquestube shunts

Autor:innen und Institutionen

  • Ophthalmology Department, Fundación Oftalmológica Médica de la Comunidad Valenciana (FOM), Valencia, Spain.
  • Ophthalmology Glaucoma Department, Fundación Oftalmológica Médica de la Comunidad Valenciana (FOM), Valencia, Spain.

ORCID-Profile: Elena Arias-García, Cristina Martinez-Gil, Gonzalo Roig-Ferreruela, Jose Vicente Piá-Ludeña

Zitieren

APA

Arias-García, E., Martinez-Gil, C., Bautista-Cortiella, M., Roig-Ferreruela, G., Piá-Ludeña, J. V., & Lanzagorta-Aresti, A. (2025). Removal of aqueous humor and conjunctival compression sutures for a dysesthesic filtering bleb: A surgical technique and case report. European Journal of Ophthalmology. https://doi.org/10.1177/11206721241304157

Vancouver

Arias-García E, Martinez-Gil C, Bautista-Cortiella M, Roig-Ferreruela G, Piá-Ludeña JV, Lanzagorta-Aresti A. Removal of aqueous humor and conjunctival compression sutures for a dysesthesic filtering bleb: A surgical technique and case report. European Journal of Ophthalmology. 2025. doi:10.1177/11206721241304157

BibTeX
@article{AriasGarca2025,
  author = {Arias-García, Elena and Martinez-Gil, Cristina and Bautista-Cortiella, Marc and Roig-Ferreruela, Gonzalo and Piá-Ludeña, Jose Vicente and Lanzagorta-Aresti, Aitor},
  title = {Removal of aqueous humor and conjunctival compression sutures for a dysesthesic filtering bleb: A surgical technique and case report},
  journal = {European Journal of Ophthalmology},
  year = {2025},
  doi = {10.1177/11206721241304157}
}
Kostenlos starten →