Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Jonas Neubauer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University Eye Hospital, Eberhard Karls University, Elfriede-Aulhorn Str. 7, 72076, Tübingen, Germany. StudyJN@Outlook.c…. Hauptthemen laut MEDLINE: Glaucoma Drainage Implants, Stents, Intraocular Pressure. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Tübingen.
Abstract (Originalsprache)
Purpose
The success of XEN Gel Stent (XEN) and Preserflo MicroShunt (Preserflo) implantation depends mainly on the development of bleb fibrosis. This study aimed to describe the histological findings of bleb fibrosis after XEN and Preserflo surgery.
Methods
This retrospective study included patients with different types of glaucoma who underwent revision surgery after XEN or Preserflo implantation. The available clinical information and histological samples of removed fibrotic tissue were analyzed.
Results
Thirty-six patients were included. Revision surgery was performed at a median of 195 (range = 31–1264) days after primary surgery. The mean intraocular pressure changed from 29.1 (± 10.3) mmHg at baseline to 18.3 (± 8.7) mmHg (− 37%; p < 0.0001) and 16.2 (± 4.2) mmHg (− 45%; p < 0.0001) after 6 and 12 months, respectively. Histological analysis revealed an increase in activated fibroblasts and macrophages in all specimens and a parallel orientation of fibroblasts in a minor part of the probe in 60% of the specimens. No pronounced inflammatory reaction in the form of lymphocytic or granulocytic infiltration was observed. The comparison of specimens from uveitic glaucoma and primary open-angle glaucoma patients revealed no significant differences.
Conclusions
The histological analysis of fibrotic blebs from the XEN and Preserflo implants did not show any pronounced immune or foreign-body reaction and revealed a similar histological pattern of failed blebs after trabeculectomy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, University Eye Hospital, Eberhard Karls University, Elfriede-Aulhorn Str. 7, 72076, Tübingen, Germany. StudyJN@Outlook.com.
- Department of Ophthalmology, University Eye Hospital, Eberhard Karls University, Elfriede-Aulhorn Str. 7, 72076, Tübingen, Germany.
Förderung
- Universitätsklinikum Tübingen
Zitieren
APA
Neubauer, J., Suesskind, D., Gassel, C. J., Nasyrov, E., & Voykov, B. (2024). Histopathological findings of failed blebs after microinvasive bleb surgery with the XEN Gel Stent and Preserflo MicroShunt. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06479-w
Vancouver
Neubauer J, Suesskind D, Gassel CJ, Nasyrov E, Voykov B. Histopathological findings of failed blebs after microinvasive bleb surgery with the XEN Gel Stent and Preserflo MicroShunt. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-024-06479-w
BibTeX
@article{Neubauer2024,
author = {Neubauer, Jonas and Suesskind, Daniela and Gassel, Caroline J and Nasyrov, Emil and Voykov, Bogomil},
title = {Histopathological findings of failed blebs after microinvasive bleb surgery with the XEN Gel Stent and Preserflo MicroShunt},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2024},
doi = {10.1007/s00417-024-06479-w}
}
EUVIMED